background image

Page 4

SKU 97080

For technical questions, please call 1-800-444-3353.

SERVICE

Tool  service  must  be  performed  only  by  qualified  repair  personnel.    Service  or 

1. 

maintenance performed by unqualified personnel could result in a risk of injury.

When servicing a tool, use only identical replacement parts.  Follow instructions 

2. 

in  the  “Inspection,  Maintenance, And  Cleaning”  section  of  this  manual.    Use  of 
unauthorized parts or failure to follow maintenance instructions may create a risk 
of electric shock or injury.

SPECIFIC SAFEtY RuLES ANd PRECAutIONS

CAutION!  

1. 

Your Warranty is voided if:  

You drop the Air Compressor.  Always lift 

the Air Compressor using its Handle.

Do not expose to a high-dust environment. Dusty conditions may increase wear on 

2. 

the Compressor.

dANGER!

3. 

  This Air Compressor is NOT equipped and should not be used “as-is” 

to  supply  breathing  air.    For  any  application  of  air  for  human  consumption,  you 

must fit the Air Compressor with suitable in-line safety and alarm equipment (not 

included).  This additional equipment is necessary to properly filter and purify the air 

to meet minimal specifications for Grade D breathing as described in Compressed 

Gas Association Commodity Specification G 7.1-1966, OSHA 29 CFR 1910. 134, 

and/or Canadian Standards Associations (CSA).  In the event the Air Compressor 
is used for the purpose of breathing air application and proper in-line safety and 
alarm  equipment  is  not  simultaneously  used,  existing  warranties  are  void,  and 
Harbor Freight Tools disclaims any liability whatsoever for any loss, personal injury, 
or damage.

dANGER! 

4. 

 Never attempt to repair or modify the Air Tank (53).  Welding, drilling, 

or any other modification will weaken the Tank resulting in damage from rupture or 

explosion.  Always replace worn, cracked, or damaged Tanks.

Maintain  labels  and  nameplates  on  the Air  Compressor.    These  carry  important 

5. 

information.    If  unreadable  or  missing,  contact  Harbor  Freight  Tools  for  a 
replacement.

WARNING!  

6. 

Never use plastic (PVC) pipe for compressed air; serious injury or death 

could result.  Any tube, pipe, or hose used must have a pressure rating higher than 
150 PSI.  Minimum recommended pipe size:  Up to 50 feet long use 1/2” diameter.  
Greater than 50 feet use 3/4” diameter.  Larger diameter pipe is always better.

Make sure all tools and equipment used with the Air Compressor are rated to the 

7. 

appropriate capacity.  Do not use any tool or equipment that does not operate from 
85 PSI to 100 PSI.

 

 

 

Содержание 97080

Страница 1: ...hts reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual ma...

Страница 2: ...Write the invoice number on the inside of the front cover Keep this manual and invoice in a safe and dry place for future reference GENERAL SAFETY RULES AND PRECAUTIONS WARNING READ AND UNDERSTAND ALL...

Страница 3: ...bles better control of the air tool in unexpected situations Use safety equipment Always wear ANSI approved safety impact 6 glasses dust mask respirator and hearing protection during use TOOL USE AND...

Страница 4: ...D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 and or Canadian Standards Associations CSA In the event the Air Compressor is used for th...

Страница 5: ...authorized people to handle or play with the Air 15 Compressor Do not modify the factory set pressure shutoff or startup switches This tool will do 16 the work better and safer at the speed and capaci...

Страница 6: ...ave a three wire cord and three prong grounding plug The plug must be connected to a properly grounded outlet If the tool should electrically malfunction or break down grounding provides a low resista...

Страница 7: ...ing or broken please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible ASSEMBLY INSTRUCTIONS CAUTION 1 Always make sure the Compressor s Power Switch 45 is...

Страница 8: ...in line shutoff valve is an important safety device because it controls the air supply even if the air hose is ruptured Note If an automatic oiler system is not used add a few drops of Pneumatic Tool...

Страница 9: ...closed Pull on the Safety Valve 25 to verify that it is not stuck See Figures B and C Plug the Power Cord 35 into the nearest 120 volt grounded electrical outlet 2 Push in the ON side of the ON OFF Po...

Страница 10: ...OTE When the maximum air pressure 100 PSI is reached as indicated by the Tank Pressure Gauge 26 the motor will stop The Compressor will automatically restart when the air pressure drops below 85 PSI S...

Страница 11: ...inspect the general condition of the Air Compressor Check for loose screws misalignment or binding of moving parts cracked or broken parts damaged electrical wiring loose air fittings and any other c...

Страница 12: ...gulator 1 25 Safety Valve 1 26 Tank Pressure Gauge 1 27 Two Way Valve 1 29 Muffler Board 1 30 Screw M3 x 6 4 31 Copper Connector Rod 2 32 Copper Hoop 2 33 Screw M6 x 25 4 Part Description Qty 34 Dampi...

Страница 13: ...Page 13 SKU 97080 For technical questions please call 1 800 444 3353 ASSEMBLY DIAGRAM 70 26...

Страница 14: ...purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to...