background image

Page 7

SKU 97080

For technical questions, please call 1-800-444-3353.

SYMbOLOGY

Double Insulated

Canadian Standards Association

Underwriters Laboratories, Inc.

V~

Volts Alternating Current

A

Amperes

n0 xxxx/min.

No Load Revolutions per Minute (RPM)

uNPACKING

When  unpacking,  check  to  make  sure  all  the  parts  shown  on  the  Parts  List  are 

included.  If any parts are missing or broken, please call Harbor Freight Tools at the number 
shown on the cover of this manual as soon as possible.

ASSEMbLY INStRuCtIONS

CAutION! 

1. 

  Always  make  sure  the  Compressor’s  Power  Switch  (45)  is  in  its 

“STOP” position prior to performing any service, maintenance, or cleaning of the 
Compressor.

To attach the Handle (47), align the two mounting holes in the Handle with the two 

2. 

threaded  mounting  holes  in  the  Bracket  on  the Air  Tank  (53).    Then  secure  the 
Handle to the Air Tank using two Screws (46).  

(See Figure A.)

Handle (47)

Figure A

Pressure Regulator 

            (24)  

Screw (46)

 

 

 

Содержание 97080

Страница 1: ...hts reserved No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools Diagrams within this manual ma...

Страница 2: ...Write the invoice number on the inside of the front cover Keep this manual and invoice in a safe and dry place for future reference GENERAL SAFETY RULES AND PRECAUTIONS WARNING READ AND UNDERSTAND ALL...

Страница 3: ...bles better control of the air tool in unexpected situations Use safety equipment Always wear ANSI approved safety impact 6 glasses dust mask respirator and hearing protection during use TOOL USE AND...

Страница 4: ...D breathing as described in Compressed Gas Association Commodity Specification G 7 1 1966 OSHA 29 CFR 1910 134 and or Canadian Standards Associations CSA In the event the Air Compressor is used for th...

Страница 5: ...authorized people to handle or play with the Air 15 Compressor Do not modify the factory set pressure shutoff or startup switches This tool will do 16 the work better and safer at the speed and capaci...

Страница 6: ...ave a three wire cord and three prong grounding plug The plug must be connected to a properly grounded outlet If the tool should electrically malfunction or break down grounding provides a low resista...

Страница 7: ...ing or broken please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible ASSEMBLY INSTRUCTIONS CAUTION 1 Always make sure the Compressor s Power Switch 45 is...

Страница 8: ...in line shutoff valve is an important safety device because it controls the air supply even if the air hose is ruptured Note If an automatic oiler system is not used add a few drops of Pneumatic Tool...

Страница 9: ...closed Pull on the Safety Valve 25 to verify that it is not stuck See Figures B and C Plug the Power Cord 35 into the nearest 120 volt grounded electrical outlet 2 Push in the ON side of the ON OFF Po...

Страница 10: ...OTE When the maximum air pressure 100 PSI is reached as indicated by the Tank Pressure Gauge 26 the motor will stop The Compressor will automatically restart when the air pressure drops below 85 PSI S...

Страница 11: ...inspect the general condition of the Air Compressor Check for loose screws misalignment or binding of moving parts cracked or broken parts damaged electrical wiring loose air fittings and any other c...

Страница 12: ...gulator 1 25 Safety Valve 1 26 Tank Pressure Gauge 1 27 Two Way Valve 1 29 Muffler Board 1 30 Screw M3 x 6 4 31 Copper Connector Rod 2 32 Copper Hoop 2 33 Screw M6 x 25 4 Part Description Qty 34 Dampi...

Страница 13: ...Page 13 SKU 97080 For technical questions please call 1 800 444 3353 ASSEMBLY DIAGRAM 70 26...

Страница 14: ...purchase date and an explanation of the complaint must accompany the merchandise If our inspection verifies the defect we will either repair or replace the product at our election or we may elect to...

Отзывы: