FIRESTAR COMBUSTION CONTROLLER - VERSION 6.7 • OPERATION MANUAL

Overview

FireStar Combustion Controller

Status

Fan

Primary

Secondary Connected

Power

IGNITION

AIR

1

3

2

7

6

5

4

8

The FireStar Combustion Controller uses a number of sensors and 

sophisticated programming to optimize the operation of the outdoor furnace. 

The controller will automatically adjust the amount of primary and secondary 

air to optimize the gasification process, making the outdoor furnace more 

efficient and clean burning. Some of the variables used by the controller can be 

changed, allowing you to tailor the furnace operation to your heat load and to 

the type of wood being burned.

If the controller detects an abnormal condition (for example, the water level is 

low or the fire has gone out because there is no more wood in the firebox), the 

controller will display a message to alert you.

Before operating the FireStar Combustion Controller, become familiar with 

the information the control panel provides and with the procedures for making 

changes to settings.

1. 

Power button

 - used to turn the FireStar Combustion Controller on and 

off. It does not disable all electrical power to the furnace. To disable 

electrical power to the outdoor furnace, turn off the power using the 

circuit breaker in the pump compartment.

2. 

LED display

 - alternates between the furnace water temperature (displays 

for 6 seconds) and the combustion temperature in the Reaction Chamber 

(displays for 3 seconds). Other information will also be displayed on the 

LED display depending on setting, modes, alarms, warnings, etc.

3. 

Down arrow button

 - if quickly pressed four times, the display will stop 

alternating and will be fixed on water temperature. The far right decimal 

point will be illuminated when this feature is active.

4. 

Up arrow button

 - if pressed during normal operation, the LED display will 

show the combustion temperature in the Reaction Chamber.

Содержание Fire Star

Страница 1: ...ER Save This Manual For Future Reference 1 AUG 2018 p n 9000645 For parts and accessories service or repairs call your authorized Central Boiler dealer or heating contractor Record the information bel...

Страница 2: ......

Страница 3: ...5 Standby Idle 5 Idle Pulse 6 Demand Mode Low 6 Demand Mode Medium 6 Demand Mode High 7 IdleTransition Mode 7 Door Open 8 Ignition Air 8 Basic Controller Features 9 AdjustingWaterTemperature Setpoint...

Страница 4: ...sage to alert you Before operating the FireStar Combustion Controller become familiar with the information the control panel provides and with the procedures for making changes to settings 1 Power but...

Страница 5: ...actuator will open helping to light the fire in the firebox Outdoor Furnace Operation Power When the controller is off the LED display will be off To turn the controller on or off press the Power butt...

Страница 6: ...Temperature Setpoint minus the Water Temperature Differential the controller will enter Demand Mode In Demand Mode the primary air actuator will slowly open to the correct setting for the furnace mod...

Страница 7: ...Status Fan Primary Secondary Connected Power IGNITION AIR As the water temperature setpoint is reached in Demand Mode the primary air actuator will close to stop combustion and the Primary status LED...

Страница 8: ...cools to less than 550 F The Secondary status LED will be illuminated while the actuator is open DOOR OPEN will be displayed in the LED display Ignition Air Status Fan Primary Secondary Connected Pow...

Страница 9: ...ton at the same time This monitor will reset to 00 00 each time the furnace is loaded with wood i e the firebox door is left open for more than 30 seconds To manually reset this monitor press the Igni...

Страница 10: ...ter temperature displays for 6 seconds and the combustion temperature in the Reaction Chamber displays for 3 seconds during normal operation To briefly display the Reaction Chamber temperature press t...

Страница 11: ...ble to the desired setting Press the Menu button to save the setting and return to Setup Mode To Exit Setup Mode Wait 10 seconds without pressing any buttons and the controller will automatically exit...

Страница 12: ...ERATURE The idle pulse will continue until the temperature in the Reaction Chamber is above this temperature To effectively disable the pulse to temperature feature lower this value to its minimum set...

Страница 13: ...te furnace operation will stop and the display will flash special characters to indicate the update process The entire process should take about 5 minutes Do not disconnect power during this process I...

Страница 14: ...en for more than 30 seconds This will allow operation for one loading must override each loading until a repair can be made Do not override this alarm if the system has a leak NOTE If water is added t...

Страница 15: ...ction Chamber temperature until it senses that the water temperature has fallen below 195 F HIGHTEMP2 The external high limit sensor has sensed that the water temperature is above 200 F and has discon...

Страница 16: ...er BYPASS The bypass door is open if applicable to your model DOOR OPEN The firebox door is open TC1 TC2 TC3 or A 1 If the display indicates any of these messages contact your dealer STEP FAIL 1 STEP...

Страница 17: ...a 1 4 nut driver or socket remove the two screws and open the control panel 3 Remove the round plug on the left side of the control 4 Install the grommet into the hole 5 Align the antenna through the...

Страница 18: ...n LED will flash blue while it is attempting to connect When the LED is a steady green the control is connected to your network 15 If the control fails to connect the connection LED will be steady red...

Отзывы: