27
Before you service or remove parts, stop the engine and allow it to cool.
Always remove the spark plug cap from spark plug when servicing the engine
to prevent accidental starting.
After the first 10 operating hours, proceed with sump oil change, as follows:
(Ref. to Figs. 25 and 25a)
– Remove the cap with the magnetic insert (28).
– Remove the oil filler cap (07).
– Make sure that all the oil comes out by tilting slightly the
drilling machine in order to make the operation easier.
– Clean the cap (28) (see
§ 13.1.2
).
– Reassemble the cap.
– Fill the oil sump to the level indicator (see
§ 13.1.1
)
using the
oil supplied with the drilling machine; it will be necessary to
use about 100 ml oil.
– Replace the oil filler cap (07).
Ensure that disposal of used oil is
in accordance with current legislation.
13.1) ORDINARY MAINTENANCE OF THE DRILL
Every 20 hours of operation
13.1.1) Topping up oil
(Ref. to Figs. 25 and 25a)
With the drill switched off and placed on a flat surface, check
the oil level in the crankcase by looking through the transparent
inspection cover (19).
The level must be approximately half way up the cover; if the
level is low, top up the oil by unscrewing the cap (07) at the
top of the crankcase and adding the quantity of oil required.
Only use the oil grade recommended in § 1.
Never use regenerated or used oil.
The oil must be clean.
07
19
28
FIG. 25
FIG. 25a
13. MAINTENANCE