26
12. STORING THE DRILL
When work has been completed, put away the drill by proceeding as follows:
12.1)
Depressurise the tank of the
SR5000
cooling unit (see § 4), close the tap (02) on the tube
from the tank, and disconnect the quick-coupling (03).
12.2)
Carefully clean the drill, particularly in the spindle area, removing machining waste (swarf,
etc.) and any deposits of lubricating coolant.
12.3)
Fully withdraw the spindle.
12.4)
Place the drill and the
SR5000
cooling unit in a sealed place free from dust, moisture and
the risk of accidental impact.
For better protection
Cembre
recommends the use of the
VAL P24
plastic case or
VAL P24-CS
(
variant with folding handle and wheels, see Fig. 24a
)
designed for this purpose (see § 3.2). The
DBG-F2 moving arm device allows the drill to be housed and locked in the case. Suitable hous-
ings are also provided in the plastic case
for containing the most commonly used accessories.
FIG. 24a VAL P24-CS STORAGE PLASTIC CASE
RAIL DRILL
ACCESSORIES
PLASTIC CASE
ACCESSORIES