www.cellarcool.com | Page 3
QUICK REFERENCE GUIDE
Controller Layout
Refer to page 12 for complete listing of buttons and symbols.
2500 WM SPECIFICATIONS
Model
WM 2500-CR Unit
(Fan Coil Unit)
WM 2500-S Condenser
(Air Cooled Condensing Unit)
Cellar Size (cu. ft.)
500
Dimensions
20”w x 10.5”h x 13”d
11.5”w x 9.9”h x 16”d
BTUh with 90° air entering
the condenser coil.
1540
CFM
99
190
Refrigerant
R-134a
Condensing Unit HP
1/5
Voltage Rating
(20 amp
dedicated circuit required)
115V or 230V - 20 amp dedicated circuit required
Weight (lbs)
25
41
AMPS
(Starting/Running)
2/1
11/3.8
dBA
51
65
Line Set
Suction Line 3/8” od. Liquid Line 1/4” od
Drainline
1/2”
Installation
Evaporator Unit (Fan Coil Unit) is installed in the cellar. The Condensing Unit is installed up
to 100 line feet away and in accordance with the installation specifications found in the Tech
Manual.
Thermostat
Digital Control Display
Temp. Delta
55°F temperature differential
(maintains proper cellar temperature when exhaust environment does not exceed 110°F)
Warranty
2 year parts and labor
Compressor On
Unit is in Anti-Frost Mode
Fans are On
Alarm is Present
Temperature Measurement
Menu Navigation
& Value Increase
*Press and hold
to manually enter
anti-frost mode.
Power On/Off
(hold for approx. 3 seconds)
& Escape
Menu Navigation
& Value Decrease
Probe Values &
Alarm Folder
*Press and hold to
enter the parameter
menu.