Page 14 | 1-855-235-5271
CWM
021014
MAINTENANCE SCHEDULE
Monthly
1. Check for debris surrounding condensing unit(i.e. leaves, branches, trash ect).
Remove all obstructions.
2. Check for unusual noise or vibration
3. Check the drain line to see if it is above the waterline if draining into a vessel.
Quarterly 1.
Use a vacuum with brush attachment to clean the evaporator coil. Be careful not to
crush coil fins when cleaning.
2. Remove the evaporator filter and clean with warm water.
3. Ensure the condensing unit is free of debris and dust.
4. Have a certified HVAC Technician service the condensing unit/clean the condenser
coil.
Annually
1. Inspect for corrosion.
2. Check wiring connections and integrity of cords.
3. Pour a 50/50 bleach solution into the drain line every spring.