TORQUE MEASUREMENT

page 4

TORQUE MEASUREMENT

Output is available in PD, PP and C modes.  In PD and PP modes peak
data is output when ZERO is pressed or activated by the AUTO ZERO
function. In C mode, the gauge outputs data continuously 180
data/second.

GENERAL OPERATION

1. Connect the torque sensor to the tester display

unit with cable provided.  When connecting
the cable to the torque sensor, rotate the round
connector to find the matching groove, then
push in until it makes positive connection
(When disconnecting the cable from the
torque sensor, hold the silver metal part of the
round connector and pull out). 

2. To select the desired measuring unit (lbf-in, kgf-cm, N-m, N-cm),

press POWER,  then hold UNITS for 4 four seconds until a beep
sounds. Press UNITS to cycle choices. Press PRG/SET to enter.

3. Press and hold MODE for one second to select from the follow-

ing Measuring Modes.

Real Time–

Displays torque transients (no output or indicator)

PP Mode–

Peak, captures peak torque (peak data output, PP
appears on display)

PD Mode–

First Peak, capture first peak value (peak data
output, PD appears on display)

C Mode–

Continuous RS-232 output Display and output
torque transients (180 data/sec., GOOD indicator

flashes)

4.   Insert Phillips tip into the screwdriver sensor.
5. Select ratchet operation by turning the ratchet

one click clockwise or counter-clockwise from
the center position. To disable ratcheting, turn
the ratchet so the semi circle is in the center
position.

6. Press the CLEAR button on the display unit or

the button on the screwdriver to zero the dis-
play. Insert the screwdriver tip into the screw,
hold perpendicularly (not at an angle), and
turn to measure.

7. After measuring, press CLEAR on the display

unit or the button on top of the screwdriver
sensor to zero the display for the next test.

6

Содержание DIS-RL2

Страница 1: ... the defective product to us with freight prepaid The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY and we hereby disclaim all other warranties express statutory or implied applicable to the products and or software including but not limited to all implied warranties of merchantability fitness non infringement results accuracy security and freedom from computer virus In no event s...

Страница 2: ... temperature high humidity or in a damp or wet areas G Recommended operating temperature is between 0 42ºC 32 100ºF G Do not apply a torque exceeding the rated capacity 180 lbf in regardless of whether the unit is On or Off Avoid shock load Do not use with impact wrenches G When charging the battery be sure to use only the provided AC adapter charger exclusively G Do not use lacquer thinner or any...

Страница 3: ... 10 11 12 13 14 15 POWER Press to turn on press again to turn off click once do not hold After 10 minutes of non use the unit shuts off MODE Select Real Time PP Peak PD Peak Down or C Continuous Output mode CLEAR Reset display to zero and send data to memory LCD display Displays torque value battery icon mode units Unit Select units lbf in kgf cm N cm N m GOOD C Mode Indicator NG Indicator DOWN SH...

Страница 4: ...er 3 Press and hold MODE for one second to select from the follow ing Measuring Modes Real Time Displays torque transients no output or indicator PP Mode Peak captures peak torque peak data output PP appears on display PD Mode First Peak capture first peak value peak data output PD appears on display C Mode Continuous RS 232 output Display and output torque transients 180 data sec GOOD indicator f...

Страница 5: ...oint value Press DOWN SHIFT to move the numeric place and press the UP to select values then press PRG SET to enter 3 Peak Down Minimum PdLO After Low value is entered PdLO is displayed then the PdLO value Press DOWN SHIFT to move the numeric place and press the UP to select values then press PRG SET to enter PdLO sets a minimum torque value for Peak Down mode For example if PdLO value is set at 5...

Страница 6: ...FT to select a memory loca tion i e 0 0 1 for first location and torque value The display cycles between memory location and value Clearing Data from Memory Single clear Press MEMORY move to a memory location and when the desired memory value is displayed press CLEAR CLR is displayed Press CLEAR again to clear the data and is dis played to confirm deletion All clear Press CLEAR and hold until the ...

Отзывы: