TORQUE MEASUREMENT

TORQUE MEASUREMENT

List of Equipment

Torque Tester Display Unit

Screwdriver Sensor

2 Phillips tips

Cable

AC adapter/charger

Carrying Case

Digital Torque Tester/Wrench  

Model DIS-TW20

Accuracy: ±0.5% F.S., ±1 LSD

Read First: Safety Information

For safety, and for damage avoidance, be sure to read this manual
thoroughly.  The warranty is only valid when the product is used fol-
lowing the instructions provided within this manual.

G

Do not use tester in high temperature, high humidity, or in a
damp or wet areas.

G

Recommended operating temperature is between 0-42ºC (32-
100ºF).

G

Do not apply a torque exceeding the rated capacity (180 lbf-in),
regardless of whether the unit is On or Off.  Avoid shock load.
Do not use with impact wrenches.

G

When charging the battery, be sure to use only the provided AC
adapter/charger exclusively.

G

Do not use lacquer thinner or any solvent to clean the unit.

G

Do not disassemble or modify the unit.

1

2

3

4

5

6

6

1

2

4

3

5

Model

Capacity

lbf-in

kgf-cm

N-cm

N-m

DIS-RL2

0.10~17.40

0.10~20.00

1.0~200.0

DIS-RL10

1.0~90.0

1.0~100.0

10~1000

0.10~10.00

DIS-RL

Specifications subject to change without notice

DIMENSIONS

Содержание DIS-RL2

Страница 1: ... the defective product to us with freight prepaid The foregoing warranty constitutes the SOLE AND EXCLUSIVE WARRANTY and we hereby disclaim all other warranties express statutory or implied applicable to the products and or software including but not limited to all implied warranties of merchantability fitness non infringement results accuracy security and freedom from computer virus In no event s...

Страница 2: ... temperature high humidity or in a damp or wet areas G Recommended operating temperature is between 0 42ºC 32 100ºF G Do not apply a torque exceeding the rated capacity 180 lbf in regardless of whether the unit is On or Off Avoid shock load Do not use with impact wrenches G When charging the battery be sure to use only the provided AC adapter charger exclusively G Do not use lacquer thinner or any...

Страница 3: ... 10 11 12 13 14 15 POWER Press to turn on press again to turn off click once do not hold After 10 minutes of non use the unit shuts off MODE Select Real Time PP Peak PD Peak Down or C Continuous Output mode CLEAR Reset display to zero and send data to memory LCD display Displays torque value battery icon mode units Unit Select units lbf in kgf cm N cm N m GOOD C Mode Indicator NG Indicator DOWN SH...

Страница 4: ...er 3 Press and hold MODE for one second to select from the follow ing Measuring Modes Real Time Displays torque transients no output or indicator PP Mode Peak captures peak torque peak data output PP appears on display PD Mode First Peak capture first peak value peak data output PD appears on display C Mode Continuous RS 232 output Display and output torque transients 180 data sec GOOD indicator f...

Страница 5: ...oint value Press DOWN SHIFT to move the numeric place and press the UP to select values then press PRG SET to enter 3 Peak Down Minimum PdLO After Low value is entered PdLO is displayed then the PdLO value Press DOWN SHIFT to move the numeric place and press the UP to select values then press PRG SET to enter PdLO sets a minimum torque value for Peak Down mode For example if PdLO value is set at 5...

Страница 6: ...FT to select a memory loca tion i e 0 0 1 for first location and torque value The display cycles between memory location and value Clearing Data from Memory Single clear Press MEMORY move to a memory location and when the desired memory value is displayed press CLEAR CLR is displayed Press CLEAR again to clear the data and is dis played to confirm deletion All clear Press CLEAR and hold until the ...

Отзывы: