2
ADJUSTMENTS
WATER FLOW ADJUSTMENT
The Dispense Valves are factory adjusted for a proper Flow Rates.
[Approximate settings:
0.75 oz./sec for MILK
;
0.375 oz./sec. for COFFEE and FLAVORS
]
Exceeding this Flow Rate will cause the Mixing Chamber to overflow.
Note: To access the Water Dispense Valves, open door and remove Hoppers.
TO ADJUST WATER FLOW RATE:
1. Open door and remove hoppers. Locate Dispense Valve behind hoppers, mounted on tank.
2. Locate adjustment screw on Dispense Valve.
3. Using a
3
16
" Allen Key or flat screwdriver rotate, 1/4 turn at a time,
CLOCKWISE to decrease water flow, or
COUNTERCLOCKWISE to increase water flow.
4. Check water flow output, after each 1/4 turn.
WATER LEVEL CONTROLS
:
Under normal conditions and operation, the water level in the tank should not drop more than ½" from the probe.
If it does, the tank is not refilling fast enough. Check the water line and
water filter, they may need cleaning or replacing.
Water Inlet Valve L462A
Water Level Probe K402Q [K402A & P410A]