Cecilware GB5MF-IT Скачать руководство пользователя страница 13

 

7

INITIALIZING MODE 

The following screen signifies this presence of this mode: 
It should be noted that this is the only time the System Software Version Number (V #.##) is displayed.   

All other functions of this mode are completely transparent to the operator.  

 

NORMAL MODE 

The following is a list of functions performed by this mode: 

1.

 

Dispensing Control

 – This mode is responsible for implementing and supervising the dispensing process.  

2.

 

Water Level Control

 – This mode is responsible for maintaining the proper level of water in the reservoir tank. 

3.

 

Water Temperature Control

 – This mode is responsible for maintaining the required water temperature in the reservoir tank. 

4.

 

Sanitary (Rinse) Functions

 – This mode is responsible for annunciating and enforcing rinse warnings and lockouts. 

5.

 

Safety Functions

 – This mode is responsible for monitoring all sensors, motors, solenoids, and heaters for proper operation. 

 

RINSE MODE 

A complete rinse is initiated by simultaneously pressing the 

Rinse

 key and any 

Dispense

 key. 

 

PROGRAM MODE 

  

General Conventions 

(unless otherwise indicated)  

1.  To 

enter

 or 

exit

 Program Mode simultaneously depresses both the 

Rinse

 key and the 

Stop

 key until the buzzer sounds (approximately 1.5

seconds).  

2.  Pressing the 

Stop

 key will cause the menu to scroll up and pressing the 

Rinse

 key will cause the menu to scroll down.  

3.  The blinking LED's) signify which Hopper or Serving Size the displayed parameter corresponds to.  
4.  Pressing the 

or 

 keys individually will decrease or increase the displayed parameter respectively.  

5.  Pressing the 

and 

 simultaneously will cause the parameter to revert to a default value. 

Functions:

 

1. 

Displays total volume dispensed. 

DISPENSE TOTAL 

#######.# OZ. 

 

 

 

 

 

 

 

2. 

Displays total volume dispensed since last reset. 

DISPENSE COUNTER 

#####.# OZ. 

 

 

 

 

 

 

 

3. 

Shows hopper status, ON/OFF, for each of the 5 hoppers.  

HOPPER ON/OFF 

SELECT A KEY 

 

 

 

 

 

 

 

4. 

Selects status for each hopper by pressing 

 or 

. HOPPER 

ON/OFF

#_ IS ON 

HOPPER ON/OFF 

#_ IS OFF 

 
 

 

SERVICE MODE  

 

General Conventions: 

1.  To 

enter

 or 

exit

 Service Mode simultaneously depress both the hidden key behind the 

Cecilware Logo 

and the hidden key

behind the 

Fast Flow Logo 

 until the buzzer sounds (approximately 1.5 seconds). 

2.  Pressing the 

Stop

 key will cause the menu to scroll up and pressing the 

Rinse

 key will cause the menu to scroll down. 

3.  The blinking LED(s) signify which Hopper or Serving Size the displayed parameter corresponds to. 

4.  Pressing the 

and 

keys individually will decrease or increase the displayed parameter respectively. 

5.  Pressing the 

and 

keys simultaneously will cause the parameter to revert to a default value. 

 

Functions:

 

1. 

Displays total volume dispensed. 

DISPENSE TOTAL 

#######.# OZ. 

CECILWARE 

DISPENSER V #.## 

Содержание GB5MF-IT

Страница 1: ......

Страница 2: ......

Страница 3: ...ILLA CARAMEL CINNAMON COFFEE MILK 5 grams 4grams 5 grams 2 2 grams 20 grams CAPPUCINO S ORIGINAL 0 0 0 140 60 Fr VANILLA 135 0 0 140 60 CARAMEL 0 135 0 140 65 CINNAMON 0 0 120 140 65 ADJUSTMENT RANGE...

Страница 4: ...110 0 0 55 CARAMEL CINNAMON COFFEE CHOCOLATE MILK 4grams 5 grams 20grams CHOCOLATE HOT CHOCOLATE 0 0 0 35 20 MOCHA 0 0 40 40 10 CARAMEL 135 0 0 55 10 CINNAMON 0 110 0 55 10 ADJUSTMENT RANGE CARAMEL U...

Страница 5: ......

Страница 6: ......

Страница 7: ...l out the drip tray It should contain the following A Set of 4 Adjustable Leveling Legs and a Flare Water Inlet Fitting START UP PROCEDURE 1 Connect the dia copper waterline to the flare water inlet f...

Страница 8: ...e Valve behind hoppers mounted on tank 2 Locate adjustment screw on Dispense Valve 3 Using a 3 16 Allen Key or flat screwdriver rotate 1 4 turn at a time CLOCKWISE to decrease water flow or COUNTERCLO...

Страница 9: ...control dispensing 3 Rinse Mode This mode becomes active when the Rinse key is depressed with any dispense key The main function of this mode is to allow the operator to initiate an individual Rinse...

Страница 10: ...r burnout due to lack of water in the reservoir tank 9 Elimination of dry powder feed at the beginning of a dispense and product dilution at the end of a dispense 10 Extremely accurate dispensing cont...

Страница 11: ...turn relative to the activation opening of the Dump Valve A positive value indicates a Mixer starting at some time after the opening of the Dump Valve A negative number indicates a Mixer starting at s...

Страница 12: ...is parameter determines the minimum reservoir tank water temperature allowed before entering Low Water Temperature Lockout The minimum Low Water Temperature Lockout Set Point is 125 F The maximum Low...

Страница 13: ...key will cause the menu to scroll up and pressing the Rinse key will cause the menu to scroll down 3 The blinking LED s signify which Hopper or Serving Size the displayed parameter corresponds to 4 P...

Страница 14: ...e LCD screen will display the Auger Start Time for the indicated Hopper AUGER START TIME SELECT A KEY AUGER START TIME SEC 8 Pressing any of the Dispense keys will cause the Dispense LED s of the corr...

Страница 15: ...the following Pressing the and keys will decrease or increase Lockout temperature LOW TEMP LOCKOUT DEG F 22 If the Stop key is pressed the LCD screen will display the following If the and keys are pre...

Страница 16: ...e system is waiting to dispense If any of the Dispense Keys are pressed while this screen is being displayed the system will rinse the Hopper corresponding to the depressed key If the Rinse Key is rel...

Страница 17: ...n This screen is displayed and the system is shut down when the Fill Solenoid has been continuously energized open filling for more than five minutes during the first fill or more than 30 seconds ther...

Страница 18: ...Reset Power Switch OFF and ON 10 High Temperature Lockout Screen Definition This screen is displayed when the present water temperature is 10 F above the water temperature set point SYSTEM ERROR TEMP...

Страница 19: ...make sure the water is not touching the Probe Pull the wire and terminal out of the Probe rod If water starts flowing into the tank the Probe may be grounded due to excessive liming Check with Ohm me...

Страница 20: ...ROX BLEACH 5 25 CONCENTRATION TO 1 GALLON OF WATER AT ROOM TEMPERATURE 70 90 F Note Always start with an unopened bottle of Clorox Bleach since the solution from an opened bottle has a short life span...

Страница 21: ...f the mounting plate 4 Pull the Whipper blade off the motor shaft Notice the flat keyway on the shaft and the matching keyway inside the Whipper blade shaft It is important that these two keyways are...

Страница 22: ...om mixing chamber a Leaking Water Dispense Valve b Too much water in tank c Mixing Chamber clogged d Water Valve blocked by scales a Replace Water Dispense Dump Valve b Dispense some water from tank c...

Страница 23: ......

Страница 24: ......

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ......

Страница 29: ...P N DESCRIPTION QTY 23...

Страница 30: ......

Страница 31: ...FETY B190A B190A B138A B138A B000A B000A POWER SWITCH 120V OR 120 240V USE L299A L069A L069A WHIPPER MOTOR LH MIDDLE CD173 RH CD350 SLINGER DISC CD124 CD124 CD173 CD350 CD173 CD350 CHAMBER MOUNT GROMM...

Страница 32: ...DISPLAY LIGHT...

Страница 33: ......

Отзывы: