8. Weighing Units (Unit) 

 

Turn on scale using the

 ON/OFF

 key and wait for the zero display. 

Press and hold the 

FUNCTION

 key until "UNIT" appears on the display.   

Press 

SET/TARE

 key, the selected unit is displayed.   

Use the 

UNIT/COUNT

 key or 

HOLD/PRINT

 key to select between different units (see following table).   

Press the 

SET

 key to select the default weighing unit. It will be displayed whenever the scale is turned 

on. 

 

 

Display

 

  Conversion factor 1 g =

 

Gram   

g   

Ounce   

oz   

0.035273962 

Troy ounce   

ozt   

0.032150747 

Pound   

lb   

0.002204623 

Tael Hongkong 

tlh   

0.02671725 

Tael Taiwan   

tlt   

0.0266666 

Grain 

gn   

15.43235835 

Pennyweight 

dwt   

0.643014931 

Momme   

(mo)   

0.2667 

Tola   

tol   

0.085733338 

Carat   

ct   

Free Factor * 

FFA   

xx.xx 

 

 

 
* In order to enter an own conversion factor, press the 

UNIT/COUNT

 key or 

HOLD/PRIN

T key as 

explained above until "FFA" is displayed. Press the 

SET/TARE

 key to confirm the selection. The last 

digit begins to flash. Press the

 UNIT/COUNT

 key to increase the value; press the

 HOLD/PRINT

 key to 

decease the value. Press the 

ZERO 

key to set the next digit. When all digits are set, press the 

SET/TARE

 key to save this value. The "Free Factor" is now the current weighing unit.   

 

 

9. Backlit Display 

 

The backlit display can be set according to the applications: 
 
Turn on scale using the

 ON/OFF

 key and wait for the zero display. 

Press and hold the

 FUNCTION

 key until "UNIT" appears on the display.   

Press the 

UNIT/COUNT or HOLD/PRINT 

key several times until "bL" is displayed. Press 

SET/TARE

 

to enter back light setting. 
Press the 

UNIT/COUNT

 or 

HOLD/PRINT

 key to select setting based on below table. 

 

 

 

Содержание SD2204

Страница 1: ...1 PORTION CONTROL SCALE 22 pounds 352 ounces 10 kilograms by grams ounces troy ounces pounds Hong Kong tael Taiwan tael grains pennyweights mommes tolas carats and free factor units...

Страница 2: ...amic weighing In the event that small quantities are removed or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the scale Example s...

Страница 3: ...rox 2 hours at room temperature after it has been disconnected from the mains Avoid static charging of the material to be weighed Major display deviations incorrect weighing results are possible if el...

Страница 4: ...enter of the platform Now press the SET TARE key Short time later CAL F appears then returns automatically to the normal weighing mode Readings of the adjustment weight appear in the display An error...

Страница 5: ...ttings in the menu ZERO Zero scale 1 Weighing Mode Turn on the scale using the ON OFF key The scale will perform self test for few seconds When the zero display appears the scale is ready for operatio...

Страница 6: ...unction can be used for unit weight control fabrication control etc Turn on scale using the ON OFF key and wait for the zero display Put the target weight on the platform and tare to zero by pressing...

Страница 7: ...RE key Weigh component Press the SET TARE key Net total sum weight of components will be displayed If necessary repeat above procedures to complete the formula up to the desired final value Back to we...

Страница 8: ...tor FFA xx xx In order to enter an own conversion factor press the UNIT COUNT key or HOLD PRINT key as explained above until FFA is displayed Press the SET TARE key to confirm the selection The last d...

Страница 9: ...ner on the scale When application involves small variations of weight it is advisable to switch off this function However the weight reading will look less stable In weighing mode press and hold the F...

Страница 10: ...RINT key several times until Pr is displayed Press SET TARE key to display current setting Press the UNIT COUNT or HOLD PRINT key to select setting based on below table Display Function Pr PC Data out...

Страница 11: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 M S N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 B U1 U2 U3 CR LF d Format for error condition 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 B B B B B B B B B B B E r r o...

Страница 12: ...and corrode the electronic circuits Do not subject the scale to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and or d...

Страница 13: ...pon receipt of the unit prepaid at CDN PO Box 10947 Portland OR 97296 0947 This warranty does not cover damage in shipment or failure caused by failure to adhere to the accompanying instructions inade...

Отзывы: