CDN SD2204 Скачать руководство пользователя страница 13

 

13 

 

1-Year Limited Warranty:   

Any instrument that proves to be defective in material or workmanship (excluding batteries) within one 
year of original purchase will be repaired or replaced without charge upon receipt of the unit prepaid at: 
CDN, PO Box 10947, Portland, OR 97296-0947. This warranty does not cover damage in shipment or 
failure caused by failure to adhere to the accompanying instructions, inadequate maintenance, normal 
wear and tear, tampering, accident, misuse, unauthorized modification, obvious carelessness or abuse. 
CDN shall not be liable for any consequential or incidental damages whatsoever. 
 
 

Содержание SD2204

Страница 1: ...1 PORTION CONTROL SCALE 22 pounds 352 ounces 10 kilograms by grams ounces troy ounces pounds Hong Kong tael Taiwan tael grains pennyweights mommes tolas carats and free factor units...

Страница 2: ...amic weighing In the event that small quantities are removed or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the scale Example s...

Страница 3: ...rox 2 hours at room temperature after it has been disconnected from the mains Avoid static charging of the material to be weighed Major display deviations incorrect weighing results are possible if el...

Страница 4: ...enter of the platform Now press the SET TARE key Short time later CAL F appears then returns automatically to the normal weighing mode Readings of the adjustment weight appear in the display An error...

Страница 5: ...ttings in the menu ZERO Zero scale 1 Weighing Mode Turn on the scale using the ON OFF key The scale will perform self test for few seconds When the zero display appears the scale is ready for operatio...

Страница 6: ...unction can be used for unit weight control fabrication control etc Turn on scale using the ON OFF key and wait for the zero display Put the target weight on the platform and tare to zero by pressing...

Страница 7: ...RE key Weigh component Press the SET TARE key Net total sum weight of components will be displayed If necessary repeat above procedures to complete the formula up to the desired final value Back to we...

Страница 8: ...tor FFA xx xx In order to enter an own conversion factor press the UNIT COUNT key or HOLD PRINT key as explained above until FFA is displayed Press the SET TARE key to confirm the selection The last d...

Страница 9: ...ner on the scale When application involves small variations of weight it is advisable to switch off this function However the weight reading will look less stable In weighing mode press and hold the F...

Страница 10: ...RINT key several times until Pr is displayed Press SET TARE key to display current setting Press the UNIT COUNT or HOLD PRINT key to select setting based on below table Display Function Pr PC Data out...

Страница 11: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 M S N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 B U1 U2 U3 CR LF d Format for error condition 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 B B B B B B B B B B B E r r o...

Страница 12: ...and corrode the electronic circuits Do not subject the scale to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and or d...

Страница 13: ...pon receipt of the unit prepaid at CDN PO Box 10947 Portland OR 97296 0947 This warranty does not cover damage in shipment or failure caused by failure to adhere to the accompanying instructions inade...

Отзывы: