CDN SD2204 Скачать руководство пользователя страница 5

 

Battery Status 

If the batteries are exhausted, "

LO

" appears in the display. Press 

ON/OFF

 key and replace the batteries 

immediately.   
If the scale is not used for a longer time, take out the battery and store it separately. Leaking battery 
liquid could damage the scale.   
 

 
Operating Instructions 
 

Key 

Function

 

ON/OFF

 

Turn on/off power of the scale

 

FUNCTION

   

Call up menu (keep key pressed until UNIT 
appears) 

 

SET/TARE

 

Ÿ

 

Confirm settings in the menu 

 

Ÿ

 

Save and exit menu 

 

Ÿ

 

Tare weight

 

UINT/COUNT

   

Ÿ

 

Select weighing unit

 

Ÿ

 

Change settings in the menu

 

Ÿ

 

Parts counting

 

HOLD/PRINT

 

Ÿ

 

Display hold 

 

Ÿ

 

Calculate weighing data via interface

 

Ÿ

 

Change settings in the menu

 

ZERO

 

Zero scale

 

 

 

1. Weighing Mode

 

Turn on the scale using the 

ON/OFF

 key.   

The scale will perform self-test for few seconds. When the zero display appears, 

the scale is 

ready for 

operations.

 

 

Important:

 If the display not showing zero, press the 

ZERO

 key. 

 

 

Place objects onto the center of platform. Take care that the weighed material should not touch the 
scale housing.

 

 

Now the weight is displayed. Once the reading is stable, the weighing unit (e.g. g or kg) will appear on 
the right-hand side of the display. If the objects are heavier than the weighing capacity, the display will 
show "

Error

" (=Overload). 

 

 
 

2.Tare

 

Turn on the scale using the 

ON/OFF

 key and wait for the zero display.   

Put the tare vessel on the platform and press the

 SET/TARE

 key. The scale display goes to zero. The 

weight of the vessel is now saved. 

Содержание SD2204

Страница 1: ...1 PORTION CONTROL SCALE 22 pounds 352 ounces 10 kilograms by grams ounces troy ounces pounds Hong Kong tael Taiwan tael grains pennyweights mommes tolas carats and free factor units...

Страница 2: ...amic weighing In the event that small quantities are removed or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the scale Example s...

Страница 3: ...rox 2 hours at room temperature after it has been disconnected from the mains Avoid static charging of the material to be weighed Major display deviations incorrect weighing results are possible if el...

Страница 4: ...enter of the platform Now press the SET TARE key Short time later CAL F appears then returns automatically to the normal weighing mode Readings of the adjustment weight appear in the display An error...

Страница 5: ...ttings in the menu ZERO Zero scale 1 Weighing Mode Turn on the scale using the ON OFF key The scale will perform self test for few seconds When the zero display appears the scale is ready for operatio...

Страница 6: ...unction can be used for unit weight control fabrication control etc Turn on scale using the ON OFF key and wait for the zero display Put the target weight on the platform and tare to zero by pressing...

Страница 7: ...RE key Weigh component Press the SET TARE key Net total sum weight of components will be displayed If necessary repeat above procedures to complete the formula up to the desired final value Back to we...

Страница 8: ...tor FFA xx xx In order to enter an own conversion factor press the UNIT COUNT key or HOLD PRINT key as explained above until FFA is displayed Press the SET TARE key to confirm the selection The last d...

Страница 9: ...ner on the scale When application involves small variations of weight it is advisable to switch off this function However the weight reading will look less stable In weighing mode press and hold the F...

Страница 10: ...RINT key several times until Pr is displayed Press SET TARE key to display current setting Press the UNIT COUNT or HOLD PRINT key to select setting based on below table Display Function Pr PC Data out...

Страница 11: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 M S N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 B U1 U2 U3 CR LF d Format for error condition 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 B B B B B B B B B B B E r r o...

Страница 12: ...and corrode the electronic circuits Do not subject the scale to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and or d...

Страница 13: ...pon receipt of the unit prepaid at CDN PO Box 10947 Portland OR 97296 0947 This warranty does not cover damage in shipment or failure caused by failure to adhere to the accompanying instructions inade...

Отзывы: