The taring process can be repeated any number of times, e.g. when adding several components for a 
mixture (adding).   
The limit is reached when the total weight reaching full capacity of the scale. After removing the tare 
vessel, the total weight is displayed as negative reading.   
After finishing the weighing process, press the

 SET/TARE

 key again, the scale display goes back to 

zero.   
 
 

3. Pre-Tare Function 

 

Using this function the weight of a tare vessel can be stored.   
This value also remains saved if the scale meanwhile has been switched off and switched on again. 
Turn on scale using the 

ON/OFF

 key and wait for the zero display. 

Put tare vessel on the platform. Press the 

UNIT/COUNT

 key until scale displays "5 PCS". 

P

ress the 

UNIT/COUNT

 key 6 times until "PtArE" flashes on the display. By actuating the 

SET/TARE

 key, the 

current weight on the platform is saved as Pre-Tare weight.   
To switch off this function, unload the platform. Press 

ZERO

 key if display is not showing zero. Press 

the 

UNIT/COUNT

 key until scale displays "5 PCS". 

P

ress the 

UNIT/COUNT

 key 6 times until "PtArE" 

flashes on the display. Press the 

SET/TARE

 key, the stored Pre-Tare weight is deleted.   

 
 

4. Target Weighing

 

This function can be used for unit weight control, fabrication control etc... 
Turn on scale using the 

ON/OFF

 key and wait for the zero display. 

Put the target weight on the platform and tare to zero by pressing the 

ZERO

 key. Remove the target 

weight.   
Put the test objects subsequently on the platform, the respective deviation from the target weight is 
displayed with the sign "+" or "-".   
According to the same procedure, packages with the same weight can be produced with referencing to 
a target weight.   
Back to weighing mode by pressing the 

ZERO

 key. 

 

 

5. 

Counting Mode

 

Turn on scale using the 

ON/OFF

 key and wait for the zero display. 

Press the 

UNIT/COUNT

 key until scale displays "5 PCS". By pressing the 

UNIT/COUNT

 key several 

times, more reference quantities 10, 20, 25 and 50 can be called up.   
Place the same number of pieces to be counted on the platform as the reference quantity.   
Confirm with

 SET/TARE

 key.   

The scale is now in counting mode, counting all units on the platform. 

Important:

 The larger the reference quantity, the more accurate the count.   

By pressing the 

UNIT/COUNT

 key the scale returns to the weighing mode and displays the weight of 

the counted units. 

 

Note:

 If the weight is less than the 10 g, the display appears "Er 1". Use UNIT/COUNT key to return to 

weighing mode.   

Note:

 Tare vessels can also be used for piece counting. Pre-tare the weight of the tare vessel prior to 

piece counting. 

 

Содержание SD2204

Страница 1: ...1 PORTION CONTROL SCALE 22 pounds 352 ounces 10 kilograms by grams ounces troy ounces pounds Hong Kong tael Taiwan tael grains pennyweights mommes tolas carats and free factor units...

Страница 2: ...amic weighing In the event that small quantities are removed or added to the material to be weighed incorrect weighing results can be displayed due to the stability compensation in the scale Example s...

Страница 3: ...rox 2 hours at room temperature after it has been disconnected from the mains Avoid static charging of the material to be weighed Major display deviations incorrect weighing results are possible if el...

Страница 4: ...enter of the platform Now press the SET TARE key Short time later CAL F appears then returns automatically to the normal weighing mode Readings of the adjustment weight appear in the display An error...

Страница 5: ...ttings in the menu ZERO Zero scale 1 Weighing Mode Turn on the scale using the ON OFF key The scale will perform self test for few seconds When the zero display appears the scale is ready for operatio...

Страница 6: ...unction can be used for unit weight control fabrication control etc Turn on scale using the ON OFF key and wait for the zero display Put the target weight on the platform and tare to zero by pressing...

Страница 7: ...RE key Weigh component Press the SET TARE key Net total sum weight of components will be displayed If necessary repeat above procedures to complete the formula up to the desired final value Back to we...

Страница 8: ...tor FFA xx xx In order to enter an own conversion factor press the UNIT COUNT key or HOLD PRINT key as explained above until FFA is displayed Press the SET TARE key to confirm the selection The last d...

Страница 9: ...ner on the scale When application involves small variations of weight it is advisable to switch off this function However the weight reading will look less stable In weighing mode press and hold the F...

Страница 10: ...RINT key several times until Pr is displayed Press SET TARE key to display current setting Press the UNIT COUNT or HOLD PRINT key to select setting based on below table Display Function Pr PC Data out...

Страница 11: ...2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 M S N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 B U1 U2 U3 CR LF d Format for error condition 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 B B B B B B B B B B B E r r o...

Страница 12: ...and corrode the electronic circuits Do not subject the scale to excessive force shock dust temperature or humidity which may result in malfunction shorter electronic life span damaged battery and or d...

Страница 13: ...pon receipt of the unit prepaid at CDN PO Box 10947 Portland OR 97296 0947 This warranty does not cover damage in shipment or failure caused by failure to adhere to the accompanying instructions inade...

Отзывы: