29
Mains electrical connection
Warning! this appliance must be earthed
The appliance must be connected by a qualified electrician, who is a
member of the N.I.C.E.I.C. and who will comply with the I.E.T. and local
regulations.
This hob is intended to be connected to permanent, fixing wiring and
dependent on the power configuration is possible to be connected
to a 13A supply or connected via a 13A plug. The table below shows
the recommended size of cable and the fuse that will be required for
each power configuration mode.
The following diagram shows the mains connection terminal block:
Terminal connections:
2.8kW mode
When the hob is configured in 2.8kW mode it can be connected via a
standard 13A switched fused spur.
L1
N
= Brass/copper bridge link
Fig.6
Power configuration mode
Mains cable size (CSA, mm2)
Min. Fuse protection required
2.8kW
1.5
13
3.7kW
1.5
16
6.0kW
2.5 - 4.0
25
7.4kW
2.5 - 4.0
32
9
fast frying steaks