background image

 

To make  the f irst Door Phone extension as a normal Extension, program as below

:

 

       Dial #

0000  + 800  # 

Door  Phone ring assignment

 

       Dial #

0000  + 82 N #  - To assign extensions to ring when  Door Phone calls.  

                     Where,  N= 1 

– 6 (Representing  the Extension numbers from 601 to 606) 

           Repeat the  program f or up to 3 Extensions maximum except door phone. 
       Dial #

0000  + 82 # - To  clear all programmed extensions f or Door Phone calls.  

 

.

 

.

 

                                                             Emergency Call                                                                         

.

 

When  any extension dials # 88, all extensions start ringing. All extensions get connected to the extension who had dialed 
the Emergency code. All can  talk in conf erence. 

 

.

                                                                                      

Extension to Extension call                                                                

.

 

Extension numbers  in def ault are  f rom 601 to 606  and can be changed to 2 digits, 3 digits or 4 digits numbering as 
explained under the heading “Flexible Numb ering”. 

 

.

                                                                                                                                    

Flash Time setting                                                                        

.

 

The  Flash time of  the PBX can  be changed as described below: 
Dial #

0000  + Dial 00  L # 

                   Here,  L= 1  (f or 0.8 secs) 
                                  2  (f or 1.0 secs) 
                                  3  (f or 1.2 secs) 
                                  4  (f or 1.5 secs) 
                                  5  (f or 1.8 secs) 
Def ault: 0.4 Secs 

 

.

                                                                                      

Flexible Numbering                                                                        

.

 

Extension numbers  can be changed to a desired number  of  1 digit, 2 digit, 3 digit or 4 digits f rom 11 

– 6999. 

The  numbering can  either  be 1 digit, 2digit, 3 digits or 4 digits in any combination. 
The  f lexible number cannot begin with digits 0, 7, 8 and 9. 
Procedure

:

     

       Dial #

0000  + 9000  + #  (This  also resets all the f lexible numbering of  the PBX) 

       Dial #

0000  + 9 N ABCD # 

                           Where,  N = Last digit of  the original extension number  (This  original number  always  remains   the one  
                                                that is printed on the MDF even  if   f lexible numbering is done). 
                                   ABCD = The  new  Extension number.  For less than  4 digits, dial # at the end Of  Extension Number.  
If  all the new  numbers to be made in sequence then  f ollowing programming can be done with single program. This  avoi ds 
lengthy programming: 
       Dial #

0000  + 9000  L K # 

                                       Where,  L = Length of  new numbers 

– 3 digits or 4 digits 

                                                   K = First digit of  the new numbering.  If  K=2 then the numbering  will become 201  (or 2001)   
                                                         Onwards.  Then  all those Numbers can  be changed through the f ollowing programming. 
Def ault: 601,602,  to 606 

 

.

                                                               

Hot Line to Junction                                                                       

.

 

Some or all extensions can be programmed  to get Junction Line  on lif ting the Handset.   
To dial internal  numbers,  dial

 

 on lif ting the Handset. You will get internal  dial tone of  the PBX. 

To program an extension to get a f ree Junction line  on lif ting handset , 
        Dial  #

0000  + 20  N# 

 

               Where,  N= last digit of  Extension numbers that is to be programmed f or Direct Junction Access.

 

        Dial  #

0000  + 20  # - 

To convert all Extensions in “Hot Line to Junction” mode 

        Dial  #

0000  + 21  N # - To convert NN  Extension in normal  mode.  

        Dial  #

0000  + 21  # - To convert all Extensions in normal mode. 

Note

:

 When  all Extensions are  converted to Hot Line  then  to get into the  Programming mode, lif t Handset 

– dial 

 # 

 0000   

          + Whatever  Programming to be done. 
Def ault: Normal Mode 

 

.

                                                               

Hot Line to Extension     

 

                                           

.

 

Some or all extensions can be programmed to get connected to an Extension, on lif ting the Handset.   
To dial internal  numbers,  dial

 

 on lif ting the Handset. You will get internal  dial tone of  the PBX.  

To program an extension in this mode, 
        Dial  #

0000  + 883  N XXXX# 

               Where,  N= last  digit of  Original Extension numbers that is to be programmed f or this f eature. 

Содержание 206B

Страница 1: ...ble Auto Attendant Settings Auto Call Back Auto Call Disconnection Barge In Call Forward Call Pick Up CLI Calling Line Identification CLI Transferable Internal CLI CLI Digits addition CLI Recieving Mo...

Страница 2: ...Door Locks 206B Numbered as 1 2 Numbered as 601 to 606 602 is the Operator Programming can be done from 601 602 1 1 Door Phone consumes 1 Extension port NA Installation Cabling All cables of the EPABX...

Страница 3: ...is the default Password In case of any mistake while programming keep the Handset down and pick up again Whenever a correct input is entered PBX will give one single acceptance tone and when wrong in...

Страница 4: ...666 d Play Welcome Message again 0000 1665 Default Call is transferred to Operator Auto Call Back From Busy Junction Lines To get a call back when any of the busy Junction lines get free following is...

Страница 5: ...0 184 TT Where TT 01 99 Ring Time in seconds Default value 20 secs Note The time entered here should be less than the Internal Call Ringing Time Call Pick Up PBX has various codes for call pick up as...

Страница 6: ...For value of L refer Junction Dialing Controls This table has 16 Locations Procedure Dial 0000 41 QQ ABCD Where QQ 01 to 16 16 Locations of the Table ABCD The starting 4 digits of the Tel numbers to...

Страница 7: ...rinted on the MDF even if flexible numbering is done ABCD The new Extension number For less than 4 digits dial at the end Of Extension Number If all the new numbers to be made in sequence then followi...

Страница 8: ...s below Dial 0000 40 N L where N Last digit of Extension number L 0 The Extension can dial only the numbers starting with digits defined in Allowed Table 1 The Extension can dial all numbers 2 The Ext...

Страница 9: ...ber 1 2 M 0 for Day mode 1 for Night Mode N1 N6 Here N is the last digit of Original extension number Not the Flexible Number When all assigned extensions are busy When the extensions assigned for the...

Страница 10: ...will check the Junction dialing control for extension Storing Telephone number in memory Dial 0000 35 CC J NN Where CC Memory location 01 48 J Junction Number 1 2 or Junction Group 0 or Junction Group...

Страница 11: ...ed under stringentquality standards making itfree f rom defects in material and workmanship as per the following terms and conditions 1 The limited warranty for the system is valid for a period of twe...

Страница 12: ...s loss or impairmentof privacy of conversation work stoppage or loss or impairmentof data arising out of the use or inability to use the product 11 Copper Connections Pvt Ltd neither assumes nor autho...

Отзывы:

Похожие инструкции для 206B