10
Programming
:
Dial f rom your own Extension #84* Tel No (where calls are to be diverted to ) #
Increasing or decreasing the Talk time in such f orward ed calls
:
#84TT
Where, TT= 01 to 99.
In def ault TT = 09 x 10 = 90 Secs (80 secs talk time and 10 secs Alert Time)
To cancel the f eature, dial f rom your own Extension #84#
Making 2 Junction lines talk to each other while Ext remains out of the conversation.
Process
:
During conversation with a Junction line - Hook-Flash - #6
(To park the Call)
– 0 – Tel No (who is to
be connected to the previous Junction call)
– Hook Flash - #
- Now all 3 party can talk to each other.
but Ext can keep Handset down. The 2 Junction lines will hear a tone af ter 2 minutes and if any of them
presses * then they can talk f or another 2 minutes. Like this they can keep extending the talk time. If * is
not pressed then the calls will disconnect. If they wish to disconnect in between then an y of them need to
dial #.
.
Memory Dialing
.
The PBX has memory f or 48 telephone number that can be dialed f rom an extension by dialing 2 digits codes. However, if
the ext is given only local dialing f acility, then it cannot dial STD number of the memory.
Memory Dialing Enable/Disable:
To Enable : Dial #*0000 + 37 0#
To Disable : Dial #*0000 + 37 1#
Def ault: Disabled
Note- If memory dialing is disabled then it will check the Junction dialing control f or extension.
Storing Telephone number in memory:
Dial #*0000 35 CC J NN#
Where CC= Memory location (01-48)
J= Junction Number (1-2) or Junctio
n Group ‘0’ or Junction Group ‘8’
NN= Telephone number (maximum 16 digits)
Note:
In case mobile numbers are not dialing properly each time, add 0 or 00 bef ore the number while adding.
Deleting memory codes:
To delete a particular dialing code: Dial #*0000+ 35 CC#
To delete all memory dialing code: Dial #*0000+ 36#
To dial a number from memory:
Dial 7CC
.
Operator Extension Setting
.
In def ault, Extension number 606 is def ined as Operator and this extension can be changed if desired by the user.
To change the Operator Extension:
Dial #
0000 + 15 N # (N = Last digit of Extn which is to be made the Operator)
Def ault: Operator Extension is 606
To call operator, Dial 9
.
Password
.
There is only one Password f or the whole PBX programming and this Password can be changed by the user. The def ault
Password is 0000.
To change the Password:
#
0000 + 09 XXXX# Here, 0000 = Def ault password
XXXX = New Password
To reset default Password:
# * # * # * #
.
PBX Version
To check the PBX Version
Dial #64
f rom CLI Phone, PBX will give a beep tone af ter that put the handset down.
When Phone is ON Hook PBX version is displayed af ter a ring.
.
Redial
To redial Telephone number on Junction Line, Dial 0 + Telephone Number
Get Engaged Tone
Press
**
on the SLT Telephone set.
Alternately, press ‘Redial’ key on Telephone Set after getting engaged tone.
.
Resetting the PBX programming
.