background image

11 

 

To reset  all the  program 

of  the PBX except Flexible numbering  & Junction Enable/Disable to def ault values,   

                                          Dial #

0000  + 0000  + #

 

To erase  only flexible numbering

  of  the PBX, Dial #

0000  + 9000  + # 

 

.

                                                                                       

Ring Time Settings                                                                 

.

 

Two  type of  ringing time can  be conf igured as explained below

:

 

Junction  Ring  to be sensed  as disconnected 

The  PBX senses the Junction line as disconnected af ter 7 secs of  the last ring voltage. This  time can be reduced or 
increased  by using the f ollowing program: 

              

Dial #

0000  + 182  TT  # 

                            Where,  TT=  50  in def ault f or 5 secs delay. Reducing  this time could give problem in CLI.  

Internal  Call Ringing Time 

This  is the time f or which an  extension keeps ringing when  an  Extension call another  Extension. 
Program

:

      Dial #

0000  + 494  TT  # 

                            Where,  TT=  01-99  secs (Def ault Value = 99  secs) 
                                             

.

                                                                 Troubleshooting                                                                     

.

 

              Problem                                                             Solution 

There  is no ring on any extension       Press RESET  Switch (nex t  to the relay)  on the SMPS card of  the PBX, twice. 
 
The  Power LED on the  f ront panel      Re-insert  the connectors of  the lead that connects  
Is ON  but there  is no dial tone on        the SMPS card to the main  card of  the PBX.  
any extension.                                     Re-insert  the connectors at both ends of  the lead. 

 
 

.

                                                          Technical Specifications                                                              

.

 

 

Switching

 

Space Division Multiplexing

 

Power  Supply                        

 

Transf ormer  type

 

Input

 

AC 80V  to  260V

 

Wattage at 220V

 

10  W 

Extension Loop Resistance  

 

Less than  600  Ohms

 

Ambient Temperature            

 

+5

C  to +45

C

 

Ambient Humidity                  

 

95% Maximum

 

Telephone  Sets                     

 

Pulse or DTMF dialing Phones

 

Cabling

 

2 Core  f rom every Telephone  set to the PBX

 

 

.

                                                              Warranty claim details                                                             

.

 

This  manual  is  also  your  Warranty  document  and  should  be  preserved  along  with  Invoice  copy  for  claiming 
warranty. 

Model Number as per the Invoice: . . . . . . . . . . . . . . . . . . . . . .  Product S.No.: . . . . . . . . . . . . . . . .  . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   
Date of purchase: . . . . . . . . . . . . . . . . . . .  . . . . . . .                    Purchaser Name: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ..   
Purchaser’s Contact No: . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   Purchaser’s Address: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. 
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . . 
Copper Connections Pvt. Ltd. warrants that this product is manufactured under stringent quality standards, making it free f rom defects in  
material and workmanship, as per the following terms and conditions: 
1.  The limited warranty for the system is valid for a period of twelve months from the date of purchase or fifteen months from th e  d a te  

of manufacture which ever is earlier. 

2.  The limited warranty extends only to the original consumer/ purchaser of the product and is not assignable or transferable to any 

subsequent purchaser/end user. 

3.  During the limited warranty period, Copper Connections Pvt. Ltd. or its authorised service netwo rk will repair or replace, a t C o p p e r 

Connections Pvt. Ltd. option, any defective product or parts thereof with a new or factory rebuild replacement items and  re tu rn  th e  
product to the consumer in working conditions. No charge will be made to the consumer f or either parts or labour in repairing or 
replacing the product. All replaced parts shall become the prope rty of Copper Connections Pvt. Ltd..                                                                                                                                                                                     

4.  Repaired product will be warranted for a balance of original warranty period. 
5.  Upon request from Copper Connections Pvt. Ltd. or its authorised service center, the consumer must provide purch ase receipt or 

other information to prove the date and place of purchase. 

6.  The consumer shall have no benef it or coverage if any of the following conditions are applicable: 

a)  The product has been subjected to abnormal use, abnormal condition, improper storage , exposure to moisture o r d a m p n e ss, 

exposure to excessive temperature or fire etc., unauthorised modifications,   unauthorised connections, unauthorised repairs 
including but not limited to use of unauthorised spare parts in repairs, misuse, neglect, abuse , accident, alteration, improper 
installation. 

b)  Copper Connections Pvt. Ltd. was not notified by consumer o f the alleged defect or malfunction of the product during the limited 

warranty period. 

c)   The product was used with or connected to equipment not fi t for use with Copper Connections Pvt. Ltd. system or used in  o th e r 

than its intended use. 

Содержание 206B

Страница 1: ...ble Auto Attendant Settings Auto Call Back Auto Call Disconnection Barge In Call Forward Call Pick Up CLI Calling Line Identification CLI Transferable Internal CLI CLI Digits addition CLI Recieving Mo...

Страница 2: ...Door Locks 206B Numbered as 1 2 Numbered as 601 to 606 602 is the Operator Programming can be done from 601 602 1 1 Door Phone consumes 1 Extension port NA Installation Cabling All cables of the EPABX...

Страница 3: ...is the default Password In case of any mistake while programming keep the Handset down and pick up again Whenever a correct input is entered PBX will give one single acceptance tone and when wrong in...

Страница 4: ...666 d Play Welcome Message again 0000 1665 Default Call is transferred to Operator Auto Call Back From Busy Junction Lines To get a call back when any of the busy Junction lines get free following is...

Страница 5: ...0 184 TT Where TT 01 99 Ring Time in seconds Default value 20 secs Note The time entered here should be less than the Internal Call Ringing Time Call Pick Up PBX has various codes for call pick up as...

Страница 6: ...For value of L refer Junction Dialing Controls This table has 16 Locations Procedure Dial 0000 41 QQ ABCD Where QQ 01 to 16 16 Locations of the Table ABCD The starting 4 digits of the Tel numbers to...

Страница 7: ...rinted on the MDF even if flexible numbering is done ABCD The new Extension number For less than 4 digits dial at the end Of Extension Number If all the new numbers to be made in sequence then followi...

Страница 8: ...s below Dial 0000 40 N L where N Last digit of Extension number L 0 The Extension can dial only the numbers starting with digits defined in Allowed Table 1 The Extension can dial all numbers 2 The Ext...

Страница 9: ...ber 1 2 M 0 for Day mode 1 for Night Mode N1 N6 Here N is the last digit of Original extension number Not the Flexible Number When all assigned extensions are busy When the extensions assigned for the...

Страница 10: ...will check the Junction dialing control for extension Storing Telephone number in memory Dial 0000 35 CC J NN Where CC Memory location 01 48 J Junction Number 1 2 or Junction Group 0 or Junction Group...

Страница 11: ...ed under stringentquality standards making itfree f rom defects in material and workmanship as per the following terms and conditions 1 The limited warranty for the system is valid for a period of twe...

Страница 12: ...s loss or impairmentof privacy of conversation work stoppage or loss or impairmentof data arising out of the use or inability to use the product 11 Copper Connections Pvt Ltd neither assumes nor autho...

Отзывы: