RSA-112Installation and Operation
5
3 Adjustments
The RSA comes adjusted from the factory to fit most common configurations, and should not need to be
adjusted in most cases. However, if adjustments do need to be performed, it is recommended that they be
done on de-energized and isolated equipment to prevent possible damage or injury.
3.1 Travel Limits
The FPE H/HL breakers come from the factory a variety of charging arm configurations. As such, the RSA can
be configured to accommodate these variations.
Before Making Travel Adjustments…
Note that the RSA comes from the factory with a specialized travel configuration. Observe the following
diagram below.
When charging the breaker, the motor handle will not return to its starting position. This is done to prevent
the motor arm from pushing the solenoid bracket away from the CLOSE and TRIP buttons.
1. Loosen the bolt holding the upper travel stop peg in place, as indicated below.