3.3 Trip Solenoid Adjustment
14. Loosen the bolt on the bottom of the left solenoid arm, as indicated below
15. Slide or rotate the arm as required to align the close solenoid to the close lever, without contacting
the fixed plate next to the lever.
Re-tighten the bolt.