DRINK WATER TANK REFILLING
DRINK WATER TANK ALARM
RECOVERY WATER TANK ALARM
SEWAGE WATER TANK ALARM
EXTERNAL STEP ALARM
PUMP LOCK
ANTI-ICE VALVE
AMPEREMETER
This function is used during the drink water refilling and shows the water level during refilling. To switch
on this function press the tank button for more than 2 sec. until the message “DRINK FILLING “
appears.
The control panel beeps in order to warn that tank is getting filled: one short beep at 85% and a long
beep at 95%.
To exit this function press buttons
ref. 05.
Alarm turns on when drink water level is lower than 10% of the tank capacity and automatically turns on
when level exceeds 20%.
Alarm is shown acoustically (when engine is off) and visually with the symbol ref. 14 and the message
“DRINK RESERVE” and with the blinking of the value in the “tank test menu”.
Alarm turns on when recovery water level exceeds 90% of total capacity and turns off automatically
when level is lower than 80%.
Alarm is shown acoustically (when engine is off) and visually with the symbol ref. 15 and the message
“WASTE FULL” and with the blinking of the value in the “tank test menu”.
Alarm turns on when recovery water level exceeds 80% of total capacity and turns off automatically
when level is lower than 30%.
Alarm is shown acoustically (when engine is off) and visually with the symbol ref. 15 and the message
“SEWAGE FULL” and with the blinking of the value in the “tank test menu”.
NB: measure is made on a four level probe: 0 - 30 - 70 - 100
Alarm turn on when external step is down and engine is on.
Alarm is shown acoustically and visually with the message “STEP OUT” and with the blinking of symbol
ref. 12.
An electronic device automatically locks the water pump after a predefined continuous service time.
Alarm is visual only, with the message “PUMP BLK” and the blinking of symbol ref. 13.
This exit for anti-ice valve of boiler and for the piezoelectric device of gas (fridge, kitchen) is always on
and is controlled by an independent minimum voltage device, that intervenes at 9,5V; the exit can be
reactivated after the intervention of the device for one minute with the button ref. 1.
The amperemeter is inside the module DS-340HY.
- It measures the current of the leisure battery.
- Measure range is -50A÷+50A, the precision is 0,1A.
- The measure happens through the differences among the charging and discharging currents; the
arrow entering with “+” symbol indicates the recharging current; the arrow exiting with the “-” symbol
indicates a discharging current.
In order to measure the charging current of a single source (battery charger, alternator, solar
panel), turn off every other source and the users
In order to measure the consumption of a single user, switch off every charge source and any
other user.
NB: - Before calibration turn off all users and sources.
- Visualized value do not include the consumption of the electronic system.
56
FUNCTIONS
28