Contact your GSE distributor.
18 BufSzMax!
The accumulative total buffer size for both the TX and RX
buffers of all four COMM ports is 4096 bytes. Displayed If
entries to the “buffer size” parameters (P207-P208) exceed
this total.
19 x06\x44\x61ta&Stop
Certain combinations of protocol are not available. The
protocol combination selections are in P201, P202 and P203.
This error occurs if an illegal protocol combination is selected.
Refer to the Communications chapter in the technical
reference manual.
20 Deflt A/D
This message appears for 1 second. It will be displayed if the
A/D calibration data gets corrupted. Contact your GSE
distributor.
21 WriteNVErr
Error reading data from the EEPROM. Possible U16 and U17
problem.
22 ReadNVErr
Error writing data to the EEPROM. Possible U16 and U17
problem.
23 CheckNVPar
Supplementary error message for above errors.
24 NVParFull!
The setup being attempted requires more EEPROM than is
currently installed.
Error Description
25 DefltSetup
Upon power-up the indicator has not found the proper codes.
Therefore all parameters have been reset to factory default
values.
26 Bad Setup
The stored data has a checksum error. Check all parameters
or re-load setup.
27 RE-BOOT!
The indicator cannot use the EEPROM for data storage, so it
is attempting to power-up again to cure the problem.