V – Recommendations for Better Results
1.- Once the engine is throttled up to operating speed and the trigger on the gun is pulled,
the diver has to find the most effective distance between the gun nozzle and the surface
to be cleaned.
The most efficient technique is to hold the tip of the nozzle 2-5 inches (5 – 12 cm) away
from the surface to be cleaned at a 25 degree angle (figure # 28). The diver needs to
observe the shape of the cavitation jet cone, at greater depths the pressure will make it
smaller, please have in mind that the wider zone of the cone is the most efficient part of
the cavitation jet. Placing the nozzle in less than 2 inches from the surface will not allow
for efficient cavitation performance and will degrade the cleaning capability of the
system.
Follow the safety regulations that may be applicable to the work being performed.
3.- If the diver operating the system must be replaced of the cleaning operation
terminated, disengage the pressure pump by pulling down the throttle to the MIN
position (figure # 29) and then release the remaining pressure in the hose by pressing the
trigger of the gun to the open position, revert to step 1 of operating instructions to start
the cleaning again.
WARNING
: Although the CaviBlaster system is safe to use when submerged in water,
the system generates a high- pressure (up to 2,800-psi) water stream, which can cause
injury when the gun is out of the water.
ALWAYS
keep the gun submerged when the
pressure pump is engaged.
Page -
8
CaviBlaster 1228-G Operations Manual
For More information please email [email protected] or all 1-(352)275-5319