8.- Connection of the water source.
A.- Feeding water with the Feed Pump:
Connect the 1” diameter clear PVC feed hose (figure # 15) to the cam-lock
plug on the inlet strainer (Figure # 16), This feed hose has the feed pump on
one end and a cam-lock socket on the other end.
Insert the electrical plug powering the feed pump into the waterproof
electrical outlet on the handle of the power unit cart (figure # 17), The plug
cannot be wrongly connected because it will fit only in the correct position.
Drop the feed pump one or two feet into the water and tie to something to
avoid going any deeper, make sure the wiring splice is kept dry prior to
starting the feed pump. Either fresh water or see water can be used with this
system.
NOTE
: The feed pump has a neoprene check valve installed in the
discharge, this valve will prevent water from draining out of the feed hose
through the feed pump when the pump is turned off, however, this valve
somewhat restricts the flow of water from the pump, if maximum water
flow is required, this valve can be removed by removing the black hose barb
fitting.
B.- Feeding with an alternate water source:
This source must supply water at a
volume grater than 12 gallons per minute at a maximum pressure of 70 psi.
Connect the water source to the inlet of the pressure pump (Figure # 16), make
sure the feed hose is connected to the pressure pump and water is present prior to
starting the unit.
Page -
4
CaviBlaster 1228-G Operations Manual
For More information please email [email protected] or all 1-(352)275-5319