These logs are explained in more detail in the following table;
Table 2 Log Event Detail
Log
Detail
Self test results
Event completed with no error or specific detail of fault shown
Power up
OCU power ON triggered
Power Down
OCU power OFF triggered
E-Stop pressed
E-Stop was pressed
Switch Totalizers for each switch
Current total activations for each switch
Battery Replaced
Batteries have been removed and replaced
Run time on batteries
Total run time since new bateries were fitted
Low Battery warning
Low Battery Warning has been triggered
RF received signal level below defined level
Received Signal Level is below -95dBm AND two of the last three
messages were missed.
Configuration change and config ID
Configuration or Program has been updated
Datalog download
Datalog has been accessed
Datalog cleared
Datalog has been cleared
Cat 3 errors
Switch read Errors have been recorded