CANplus
TM
CP640 - EN
Control Panel Operation Manual
12
9M02-1000-A001-EN
Revision B
All 16 gauges may be configured to create an application-specific view of the data. With Tech or Admin level
access, the four analog gauge pages can be configured using the following menu:
Configuration
→
Display
→
Gauges
→
Quad Gauge Pages
.
3.4 Digital Gauge Pages
Digital Gauge Pages display the same data as the Analog Gauge Pages, but in digital only format, as shown
below. To enable Digital Gauge Pages, press any of the first four buttons to show the top level button bar and
then press button 2 to cycle through the pages.
Note:
The 16 gauges are the same for Analog and Digital Gauge Pages. Adjustments in either Analog Gauge
Pages or Digital Gauge Pages affect the same gauge in the other mode.
3.5 Single Analog Gauge
Single Analog Gauge uses the entire display for a single large analog gauge. To enable the Single Analog
Gauge, press any of the first four buttons to show the top level button bar and then press button 3 to cycle
through the available gauges. The active displayed gauge is stored when power is removed.
3.6 Active Alarms
When an active alarm is received, a flashing popup window is overlaid on the current screen. The popup
includes a plain language description in addition to the standard SPN/FMI (Suspect Parameter Number/Failure
Mode Indicator) pair defined by the SAE J1939 standard. Additionally, if enabled, the beeper sounds as an
audible cue.
Note:
Standard J1939 abbreviations are used for alarms, as follows:
MS = Most Severe
MOD = Moderately Severe
LS = Least Severe
3.7 Alarm List
The Alarm List is accessed by pressing any button while an alarm popup is displayed or by pressing any of the
first four buttons to show the button bar and then button 4. Alarms not yet acknowledged are shown in white text
on a red background, while acknowledged alarms are shown in white on black. The list also indicates when the
alarm occurred if engine hours are available. The most recent alarm is displayed at the top of the list. The list can
be scrolled using buttons 1 and 2 and alarms acknowledged by pressing button 3. The Alarm List can be closed
by pressing button 5 once the alarms are acknowledged.