Address digit #4 entry and report (PSEZ and CS controllers)
, continued.
3. Press and release button #1. The controller will emit one long ‘beep’ followed by one short
‘beep’
and the green LED will flash with the short ‘beep’. This indicates you are now in the
Address Data Entry and Report Mode.
4. To select Address Digit #4 (‘Low’ digit on PSEZ controllers) Data Entry Mode, press and
release button #4. To find the present Address Digit #4 value, press and release button #4
again. The unit will emit one long beep to alert you, then will beep out the Address Digit #4
setting count with short beeps. (i.e., fourteen short beeps if the Digit is ‘E’). The green LED
will also flash each short beep/count. (‘0’ is represented by a long beep with no LED flash).
Look, listen, and count to determine the existing value. Repeat as necessary by pressing
button #4. See Address Table on page 7 of this section to convert number of ‘Beeps’ to
‘Address Digit’ setting.
5. To increment the Address Digit #4 press and release button #1. Each depression will
increment the Address Digit #4 by one, continuing from its present value until it reaches 15,
then will roll over to zero and start again. (the unit will beep each time button #1 is
depressed).
6. Press button #4 to confirm your desired setting.
7. Once you have entered the desired Address Digit #4, set the ON/OFF switch on the PS
EZ
or
CS
controller to ‘OFF’ to permanently store the Address digit #4.
Frequency Bank entry and report (PSEZ and CS Controllers).
1. Referring to Figure 5-1 above, set the ON/OFF switch on the PS controller to ‘OFF’. Make
sure the red STOP Switch on the controller is unlatched and set to the ‘RUN’ (pulled up)
position.
NOTE: Provided a Frequency and Address has been programmed in the controller,
applying power to the controller with the red STOP Switch set to ‘STOP’
(pushed down) will immediately place the Controller in a STOP message
transmit cycle. If a Frequency and Address has not been pre-programmed in the
controller, the STOP message transmit cycle cannot be sent. Instead, the
controller will emit three long beeps and reset.
2. Press and hold down buttons #1 and #2 (see figure 5-1 above) and set ON/OFF switch to
‘ON’. Pause approximately for one second or until the green LED illuminates, then release
buttons #1 and #2. The controller will emit one long ‘beep’, which means you are now in the
Main Menu
of the address and frequency program.
NOTE: The yellow LED will flash instead of the green LED when low battery voltage is
detected.
Содержание i-Key
Страница 2: ......
Страница 14: ...Page xii 01 2001 CATTRON THEIMEG TM EZ CS AT Rx Rx Tx Tx Tx Rx Rx Rx ...
Страница 20: ...Section 1 Page 6 01 2001 CATTRON THEIMEG TM This page intentionally left blank ...
Страница 44: ...Section 4 Page 4 01 2001 CATTRON THEIMEG TM ...
Страница 52: ...Section 4 Page 12 01 2001 CATTRON THEIMEG TM This page intentionally left blank ...
Страница 68: ...Section 5 Page 16 01 2001 CATTRON THEIMEG TM This page intentionally left blank ...
Страница 75: ... 01 2001 CATTRON THEIMEG TM Section 6 Page 7 Item 7 Carrying strap shoulder Part 42C 0057 ...
Страница 89: ......