Cycle and DC Delay Times
Minimum cycle times and DC reading delay times depend on the number of readings being taken.
More readings per cycle take longer to read and store, requiring longer times. The addition of
ACVG does not affect the timing of the DC readings or the overall cycle time.
Survey Type
Cycle
Delay (ms)
OFF(ms) Cycle(s)
DCVG
CIPS1
CIPS2
CIPS only
Minimum
200
1
100
Recommended
200
1
150
CIPS + DCVG
Minimum
200
1
100
170
Recommended
200
1
100
200
CIPS + 2 x DCVG
Minimum
250
1
100
220
Recommended
300
1
100
250
2Ω CIPS /
Parallel CIPS
Minimum
250
1
100
200
Recommended
400
2
150
300
2Ω CIPS + DCVG
Minimum
300
1
100
170
270
Recommended
500
2
100
250
400
2Ω CIPS + 2 x DCVG
Minimum
350
1
100
220
320
Recommended
500
2
100
300
450
DCVG /
2 x DCVG
Minimum
200
1
100
Recommended
200
1
100
4 x DCVG
Minimum
300
1
100
Recommended
300
1
100