Revised July 2020
CI-100TS Current Interrupter Manual
11
the vertical scroll buttons. Whenever the OFF time is changed, the ON time is automatically
calculated.
In the above picture, to change the OFF time to 200ms, the user should tap the third digit and scroll
down to 2.
Note:
Minimum value for OFF time is 100ms.
On/Off First:
The user can choose to have the interrupter start the cycle with the CP ON or OFF. This can be
changed by tapping the
ON/OFF First
button, located at the screen bottom between the arrows.
For example, assume that OFF time is 1 second and ON time is 3 seconds, the user can select that
once the operation is started, first turn rectifier 1 second off and then turn it on for 3 seconds:
Or, first turn rectifier 3 seconds on and then turn it off for 1
second:
Once the user has finished with this screen, tap the forward arrow to save the program.
1s
3s
3s