Revised July 2020
CI-100TS Current Interrupter Manual
10
If the user selects
YES
, adding a new program will be canceled and all newly inserted data is
removed. The user can tap
NO
to return and continue adding a new program.
Once the user has completed entering information on the current screen, tap the forward arrow to
continue the process.
Cycle Information
Any parameter the user has tapped to change will be highlighted in blue. The cycle information is
entered on the first screen:
In this screen, the user must
define the “Total cycle time”, select “On/Off First” and define “OFF
time”. The “ON time” will be calculated according to the selected cycle time and OFF time.
Cycle Time
To set the total cycle time, tap on the total cycle time to select it, then the user can use the vertical
arrows to scroll through the predefined cycle times and select the desired one.
The available cycles are: 1, 2, 3, 4, 5, 6, 10, 12, 15, 20, 30, 60 seconds.
OFF Time:
After selecting the total cycle, the length of the OFF time must be defined. The OFF time is defined
in milliseconds. The user can define the desired OFF time by tapping each digit separately and using