Page 58
The following table is a breakdown of all the possible display parameters with a
brief description. Please see the previous tables to determine which
parameters your instrument displays.
Display
Description
LAF 93.7
Frequency and Time Weighted Sound Pressure Level.
LAF = A Weighted, Fast
LAS = A Weighted, Slow
LAI = A Weighted, Impulse
LCF = C Weighted, Fast
LCS = C Weighted, Slow
LCI = C Weighted, Impulse
LZF = Z Weighted, Fast
LZS = Z Weighted, Slow
LZI = Z Weighted, Impulse
LAq 93.7
Displays the Frequency Weighted Leq
LAq = A Weighted Leq
LCq = C Weighted Leq
LZq = Z Weighted Leq
Amx 97.3
Maximum rms Sound Pressure Level – Freq Weighted
Amx = A Weighted Max Level
Cmx = C Weighted Max Level
Zmx = Z Weighted Max Level
Cpk 100.3
Maximum Peak Level Reached – Freq Weighted
Apk = A Weighted Peak Level
Cpk = C Weighted Peak Level
Zpk = Flat or Linear Weighted Peak Level
Lep 87.1
Displays the Lep,d
Do% 27.2
Dose (dependent on exchange and criterion)
Hr% 53.2
Dose per Hour
P2h 0.02
Indicates the energy that has been received in Pascal
Squared Hours
LAe 93.1
Sound Exposure Level - Freq Weighted
LAe = A Weighted Sound Exposure Level
L10 45.4
dB(A) level exceeded for n% of the time
n = 10, 90 and user selectable (L10, L90, Lxx)
O.L. NO
O.L. YES
Overload latch that indicates if an OVERLOAD has
occurred
(Can be reset by pressing the ‘C’ key in
Stop
mode)
00:01:33
Duration of
Record
mode (Measurement Time - MT)
hh:mm:ss
PER 10s
Duration of the selected Recording Interval Period
remaining – Only available in
Record
mode
—–.—
Indicates when values are 0 or significantly lower than
the bottom of the current range selected e.g. when
instrument is first powered on or after being reset whilst
in STOP mode.