43
OSHA (PEL)
Select this option for requirements meeting OSHA (PEL) legislation. Exchange Rate,
Criterion and Threshold are fixed as below: -
•
Exchange Rate = 5
•
Criterion = 90
•
Threshold = 80
When OSHA (PEL) is selected the Exposure measurement screen displays and records
the following parameters: -
•
L
AVG
, D
OSE (%)
, T
WA
Custom
Select this option to manually set legislation requirements as needed: -
•
Exchange Rate = 3, 4, 5 or 6
•
Criterion = 70, 75, 80, 85, 90 or 95
•
Threshold = Off, 70, 75, 80, 85, 90 or 95
Scroll the available options using the directional
Arrow
keys, press
OK
or the
Left
,
Right
Arrow
keys to amend the setting.
When Custom is selected the Exposure measurement screen displays and records the
following parameters: -
•
L
AVG
, D
OSE (%)
, T
WA
Содержание dBAir