9
The 999 Quick Stop/Smart Stop can also
store 80 standard frames identified only by
their length and width dimensions.
The standard frame menu is accessed either
via the Main menu or via the Execution menu.
There are 5 pages of 16 standard sizes. All
the dimensions can be reprogrammed using
the numeric keypad.
MENU MAINTENANCE PARAMETERS
All the values can be modified. There is no need to switch off the power for the new values to
be acknowledged.
RESET MEASURER : Press the measurer button and this key simultaneously to reset the meas-
urer origin, if it is incorrectly set. Beware: Take care to remove any moulding which could
have stayed on the cutting table, near the left hand horizontal presser.
STANDARD PLAY: Type the play value allowance you wish to add automatically for
internal dimension positioning, e.g. 1.5 mm.
STOP MECHANICAL OFFSET: Dimension at which the automatic stop is initialised each
time the power is switched on and the EXECUTE key is touched for the first time. This
dimension can be checked by cutting a moulding at 45° and measuring its thickness without
rebate. If necessary this dimension can be adjusted each time a stop or coder is removed. In
this case, check that the stop initialises approximately 2-3 cm beyond the proximity detector
of the origin take-up area.Modify the offset value allows you to correct directly the stop’s
position, hence to compensate a possible measuring mistake.
LOCK EXT. SIZE : Type the value ‘1’ if you do not wish the operator to be able to work
with external dimensions (the INTER/EXTER keys will be disabled).
To release, type the value ‘0’.
PIN CODE: Reserved for maintenance.
In the main menu, touch MAINTENANCE
to access the parameters page.
STANDARD SIZES:
A frame is executed by touching its key: the execution screen will appear, allowing only the
length and width values of the standard frame to be adjusted.
This allows standard frames to be combined with the SMART STOP measuring function or a
stored file.