Cassese
.
MACHINES POUR L'ENCADREMENT • FRAME MAKING MACHINES
CS
276
E
INSTRUCTIONS FOR SETTING UP BEFORE OPERATION
(accompanied with drawings Fig.1 and Fig.1.1)
Warning : DON'T PLUG THE MACHINE TO AIR OR POWER BEFORE
FOLLOWING THROUGH ALL THESE INSTRUCTIONS WITH SUCCESS.
1- (See drawing FIG 1)
In the accessories box, you will find one big handle (B)
and two small handles (X and W ) .
Remove the screws (Allen wrench No 12 and no 5) that are
put just for transportation and fix the handles.
2- Loosen the stapling position stops with handles X and
W and pull the plunger bracket (E) towards the keyboard side
as much as possible. (For security in transportation the
bracket (E) is in buttom position.)
3- Fix also the manometer (in the accessory box) on the
air regulator of the machine.
* To bring up now the plunger bracket (E) mechanism of
the machine ;
4- Remove the side grey casings of the machine by pulling
them upside. This way you get access to the inside of the
machine.
You have in the accessory box all the keys or wrenches
you need for the following instructions.
5- (See now the drawing FIG 1.1)
Loosen the rings A which are put for transportation
purposes only. Bring them completely down and tighten them so
that they do not vibrate when the machine will work.
6- Take away the adhesive band which is around the hammer
support.