17.2 Causes and rectification of faults
In the event of a fault, an error code will appear in the display; it
describes the cause of the fault.
The following table assists in localizing and rectifying minor
faults.
Fault
Possible Cause
To Rectify
E01
Electronic control of
low voltage.
(<160V)
►
Make sure the appliance
is connected to the
voltage indicated
E02
Electronic control of
excess voltage
(>270V)
►
Make sure the appliance
is connected to the
voltage indicated on the
rating label.
E03
IGBT open or short
circuit.
►
Please send back to
customer service.
E05
Overheating
protection on power
mode (>150°C)
►
Eliminate the course of
overheating. Once the
cooktop has cooled, the
appliance can be put into
operation again.
E06
Temperature sensor
open or short circuit
►
The temperature sensor
underneath the glass
ceramic plate is
defective. Please send
back to customer serivce.
E07
Overheating
protection on TEMP.
mode (>240°C)
►
Eliminate the course of
overheating. Once the
cooktop has cooled, the
appliance can be put into
operation again.
E08
Temperature sensor
malfunction
►
Please send back to
customer service.
Please
note
►
If error messages continue to be displayed after an extended
waiting period or after restarting the appliance, then it must be
sent to Customer Service to be examined.
►
If you are unable to solve the problem with the steps shown
above, please contact Customer Service.