6-5. LCD Flicker
The screen may
fl
icker depending on the combination of the LCD module and Main PCB.
Adjust the screen to minimize this
fl
icker.
DT-X100
Protection
Rubber
329802
329821 or 329811
LCD surface of DT-X100
No
Operation
Display
Test Details
1
Start up DiagPY055.
Select [Flicker control].
Set a luminance meter onto LCD of DT-
X100. Adjust the reading to be 2% or
lower by using the “UP” and “DOWN”
keys.
After the adjustment, press the “ENT”
key. This saves the setting and returns
you to the Menu screen.
6-6. Laser Calibration
Adjust a laser emission width and save the data to the Main PCB.
No
Operation
Display
Test Details
1
Start up DiagPY055.
Select [Laser Calibration].
Open a page showing
barcodes for emission
width adjustment, on
Users Guide. Adjust a
distance between a DT-
X100 Laser Filter (window)
and barcode to be 60mm.
In this state, press the
“Center” key.
Calibration is executed automatically.
If the calibration is successful, “Calibration
OK” is displayed and a laser beam lights
in order of Wide, Middle and Narrow for 1
second respectively. (repeated)
Pressing the “ENT” key turns off the
laser beam and returns you to the Menu
screen.
If the calibration fails, an error indication
is displayed . Pressing the “ENT” key
returns you to the Menu screen.
Содержание DT-X100 Series
Страница 1: ...SERVICE MANUAL Ver 2 Jun 2018 HANDHELD TERMINAL DT X100 JUN 2015...
Страница 27: ......
Страница 71: ...68 7 1 EXPLODED VIEW 1 FINAL UPPER CASE LOWER CASE INNER CASE 43 43 44 LASER model 2D model 43 43 43...
Страница 72: ...1 13 1 12...
Страница 73: ...70 3 INNER CASE 17 16 15 14 35 13 12 12 1...
Страница 74: ...19 6 1 19 6...
Страница 75: ...72 5 BUNDLED ITEMS 6 TOOLS 49 50 46 47 48 45...