— 62 —
5-8-7. Laser Scanner movement
No
Operation
Display
Inspection contents
1
Set the supply voltage to
4.0V.
Select [Laser Current] in
the test program.
Backlight is turned off.
Check that the current value is as follows.
- “150 mA” or lower (DT-X100M10 series/
M30 series)
- “250 mA” or lower (DT-X100M50R)
Within spec: Press the “1” key.
Out of spec: Press the “0” key.
Pressing “1” or “0” returns you to the
Menu screen.
5-8-8. 2D Module movement
(For DT-X100M10 series/M30 series only)
No
Operation
Display
Inspection contents
1
Set the supply voltage to
4.0V.
Select [2D Current] in the
test program.
Backlight is turned off.
Check that the current value is 360mA or
lower.
Within spec: Press the “1” key.
Out of spec: Press the “0” key.
Pressing “1” or “0” returns you to the
Menu screen.
Содержание DT-X100 Series
Страница 1: ...SERVICE MANUAL Ver 2 Jun 2018 HANDHELD TERMINAL DT X100 JUN 2015...
Страница 27: ......
Страница 71: ...68 7 1 EXPLODED VIEW 1 FINAL UPPER CASE LOWER CASE INNER CASE 43 43 44 LASER model 2D model 43 43 43...
Страница 72: ...1 13 1 12...
Страница 73: ...70 3 INNER CASE 17 16 15 14 35 13 12 12 1...
Страница 74: ...19 6 1 19 6...
Страница 75: ...72 5 BUNDLED ITEMS 6 TOOLS 49 50 46 47 48 45...