— 19 —
(5) Remove the connector of the USB-WIRE-SUB-ASSY.
Open the L-CASE-UNIT by 180 degrees.
Connector
(6) Peel off the tape TAPE/CONNECTOR-B and TAPE/CONNECTOR-C that holds down the connector.
Remove the coaxial cable of the WLAN-5G-UNIT and the FFC/SUB.
FFC/SUB
Coaxial cable
TAPE/CONNECTOR-C
TAPE/CONNECTOR-B
(7) Assemble the removed parts by reversing the disassembly procedure.
Connect the coaxial cable of the WLAN-5G-UNIT and insert the FPC-PY055VA4-SUB.
Attach the TAPE/CONNECTOR-C to the connector. After that, attach the TAPE/CONNECTOR-B to the
coaxial cable.
NOTE:
Be sure to connect the coaxial cable to the right side connector in the picture below.
Содержание DT-X100 Series
Страница 1: ...SERVICE MANUAL Ver 2 Jun 2018 HANDHELD TERMINAL DT X100 JUN 2015...
Страница 27: ......
Страница 71: ...68 7 1 EXPLODED VIEW 1 FINAL UPPER CASE LOWER CASE INNER CASE 43 43 44 LASER model 2D model 43 43 43...
Страница 72: ...1 13 1 12...
Страница 73: ...70 3 INNER CASE 17 16 15 14 35 13 12 12 1...
Страница 74: ...19 6 1 19 6...
Страница 75: ...72 5 BUNDLED ITEMS 6 TOOLS 49 50 46 47 48 45...