Casio CSP-100/2875 Скачать руководство пользователя страница 3

Operation Guide CSP-100/2875

3

Display Contents

Main display area

Kilocalorie indicator

Average pulse  
indicator

Maximum pulse 
indicator

Resting pulse 
rate indicator

Low battery indicator

Advice indicator

Total indicator

Target indicator

Aerobic mode indicator

Fat burning mode indicator

Radio on indicator

Gram indicator

Kilojoule indicator

Beats per minute 
indicator

Manual mode indicator

1

Main display area

Shows measured values and setting values.

2

Kilocalorie indicator

Displayed when an energy consumption value is in the main display
area (when kilocalories is selected as the energy unit).

3

Average pulse indicator

Displayed when an average pulse value is in the main display area.

4

Maximum pulse indicator

Displayed when a maximum pulse value is in the main display area.

5

Resting pulse rate indicator

Displayed when a resting pulse rate value is in the main display area.

6

Beats per minute indicator

Displayed when a pulse rate value is in the main display area.

7

Kilojoule indicator

Displayed when an energy consumption value is in the main display
area (when kilojoules is selected as the energy unit).

8

Gram indicator

Displayed when a body fat burned amount is in the main display
area, while kilograms (

) is selected as the weight unit.

9

Radio on indicator

Displayed on the stopwatch screen while the radio is turned on. This
indicator also appears when you are registering a frequency in
frequency memory.

0

Manual mode indicator

Displayed when “MANUAL

 is selected as the exercise mode.

A

 

Aerobic mode indicator

Displayed when “AEROBIC

 is selected as the exercise mode.

B

 

Fat burning mode indicator

Displayed when “BURNING

 is selected as the exercise mode.

C

Low battery indicator

Displayed when battery power is low. Replace the battery when this
indicator appears.

D

Advice indicator

Displayed when the Voice Exercise Advice feature is turned on.

E

Total indicator

Displayed when a total elapsed exercise time value is in the main
display area.

F

Target indicator

Displayed when the time currently in the main display area indicates
the total time you were within the target pulse range.

Power Requirements

Power is supplied by a single AAA-size alkaline battery (LR03). Use of a
battery type recommended by CASIO or its equivalent is recommended.

Replace the battery as soon as possible after the low battery indicator
(

) appears on the display.

Make sure that the (+) and (–) ends of the battery are oriented
correctly when you load it.

Be sure to remove the battery from the Pulse Monitor if you do not
plan to use it for a long time.

Failure to replace a weak or old battery can lead to malfunction.

The battery that comes with the Pulse Monitor is not a rechargeable
type. Never try to charge it.

The original battery that comes with the Pulse Monitor is loaded at the
factory before shipment. Because of time spent in transit and storage,
the original battery may not provide the specified battery life.

Should a battery ever leak, immediately wipe the fluid from inside the
battery compartment, taking care not to get any on your skin.

Keep all batteries out of the reach of small children. If a battery is
accidentally swallowed, immediately contact a physician.

Dispose of used batteries in accordance with the regulations and laws
in your particular country or area.

To load the battery

1. Use a Phillips head screwdriver to loosen the two screws that secure

the battery cover in place.

2. Use the indent at the top of the battery cover to pry it open, and then

remove the cover.

3. Making sure that its (+) and (–) ends are oriented correctly, load the

battery into the battery compartment.

4. Insert the tabs along the bottom of the battery cover into the slots at

the edge of the battery compartment, and then swing the cover into
place.

5. Secure the battery cover with its two screws.

Make sure that the areas where the battery cover contacts the battery
compartment are clean and free of foreign matter. Dirt, dust, and other
foreign matter can allow moisture to get inside the Pulse Monitor.

Auto Power Off

The Pulse Monitor will automatically turn off if there is no measurement
operation being performed and you do not perform any button operation
for about one hour. Note that this is true even if you are just listening to
the radio.

Battery cover

Screws

Battery cover

Indent

Tabs

Slots

Содержание CSP-100/2875

Страница 1: ... hearing normal sounds around you Also be sure to remove the Pulse Monitor when approaching a railroad crossing a construction site and any other area where you need to be cautious of what is going on around you Be careful with battery fluid Touching battery fluid leaking from a battery creates the risk of loss of eyesight personal injury and skin inflammation Should battery fluid ever get into yo...

Страница 2: ...tral detergent Never use thinner benzene or other chemical or any agent that contains alcohol Precautions when handling the arms The arms of the Pulse Monitor are foldable Never apply undue force when folding or unfolding the arms Be especially careful that you do not try to force the arms wider than they are designed to unfold normally Applying too much force when folding or unfolding the arms ca...

Страница 3: ...dicates the total time you were within the target pulse range Power Requirements Power is supplied by a single AAA size alkaline battery LR03 Use of a battery type recommended by CASIO or its equivalent is recommended Replace the battery as soon as possible after the low battery indicator appears on the display Make sure that the and ends of the battery are oriented correctly when you load it Be s...

Страница 4: ...th and fitness and by other factors Weight Unit Initial Default kg Use this setting to specify the unit of measurement you want to use when specifying your weight below When you plan to perform this type of exercise Light aerobics preset target pulse range Heavy aerobics preset target pulse range Exercise at an intensity level target pulse range specified by you Select this mode BURNING AEROBIC MA...

Страница 5: ...he STOP RESET ADJUST button This displays the SET screen The SET screen will also appear if you hold down the STOP RESET ADJUST button for about two seconds or if you do not perform any operation for about two or three minutes while any setting screen is on the display 21 To return to the stopwatch screen hold down the MODE SELECT button for about two seconds Holding down either button changes the...

Страница 6: ...see Performing Elapsed Time and Pulse Measurements To put on the Pulse Monitor for exercise 1 Hold down the POWER button for about two seconds to turn on power 2 With the control box positioned so it rests on the back of your neck hang the two arms on your ears as shown in the illustration so the earpieces are aligned comfortably with your ears 3 Clip the ear clip onto your earlobe as shown in the...

Страница 7: ...e and the applicable Voice Exercise Advice message 5 To stop measurement press the STOP RESET ADJUST button This stops the stopwatch elapsed time measurement and pulse monitoring and stores the results in measurement memory See Viewing Measurement Memory Contents for more information 6 After you are finished using the Pulse Monitor hold down the POWER button for about two seconds to turn off power...

Страница 8: ... optional and personal information settings See To configure optional settings and personal information settings for more information This screen Energy Consumption Body Fat Burned Total Exercise Time Time in Target Range Average Pulse Shows this information Energy you consumed while exercising Range 0 to 9 999kcal or 0 to 41 835kJ Body fat you burned while exercising Range 0 to 999 grams or 0 to ...

Страница 9: ...ng the tuning mode also will cause a simulated human voice to announce Memory or Automatic in accordance with the mode that is newly selected Memory number Frequency Earpiece left Earpiece left Using Auto Scan With Auto Scan the radio scans frequencies and automatically stops at the first receivable frequency that it finds If you have problems finding a receivable frequency with Auto Scan it could...

Страница 10: ... is attached correctly and securely 첸Are you in an area where there is electrical noise Strong electrical noise can cause pulse rate measurement errors Avoid such areas where electrical noise is being generated 첸Is your exercise causing severe vibration The Pulse Monitor is designed for use while walking Strong impact and vibration while running can make it impossible for the sensor to correctly m...

Отзывы: