2.1.1.
C4 Setting
2.1.1.1.
C4-1 Setting
B7
B6
B5
B4
B3
B2
B1
B0
Weight
Unit
External
Resolution
Display Unit
TARE
0:kg
1:lb
00: Low
01: High
00:kg
01:lb
10:oz
11:g
00: (+)One Time (-) One Time
01: (+)Successive (-) One Time
10: (+)One Time (-) Successive
11: (+)Successive (-)Successive
User should input Hexa code to set C4.
User should input “weight unit”, “external resolution”, “display unit”, and “tare”.
For example, if you want to set “kg (0)” as the weight unit, “low (00)” as the external
resolution, or “(0)” as TARE you may input “00” as Hexa value.
User can set 2,000~2,500 for low external resolution or 4,000~5,000 for high external
resolution.
2.1.1.2.
C4-2 Setting
Capacity Setting
UNIT
kg
g
lb
oz
C4-2 Value
2 2,000 5 80
0000 1XXX
5 5,000 10 160
0001 1XXX
10 10,000 20 400
0010 1XXX
PW-II has four different weight units, g, kg, lb, or oz as shown in shaded area. You can set
the capacity to input first 5 bits, for example, “00011” for 5 kg capacity.
Next three (3) bits represent “Interval” information. For example, if you set 5 kg interval the
Hexa value will be “0x18”.
2.1.1.3.
C4-3 Setting (Function Setting)
ROM VERSION 1 (Hold)
ROM Version 2 (lb)
Function Function
S-HOLD XXXX
XX00
HOLD XXXX
XX00
Lb XXXX
XX10
Downloaded from
www.Manualslib.com
manuals search engine
Содержание PW-10H
Страница 1: ...PW II Service Manual 1 PW II SERVICE MANUAL Downloaded from www Manualslib com manuals search engine...
Страница 7: ...PW II Service Manual 7 1 5 Sealing Method Downloaded from www Manualslib com manuals search engine...
Страница 17: ...PW II Service Manual 17 4 Exploded View Downloaded from www Manualslib com manuals search engine...
Страница 19: ...PW II Service Manual 19 5 2 Main PCB Rear Downloaded from www Manualslib com manuals search engine...
Страница 20: ...PW II Service Manual 20 5 3 BATTERY PCB Downloaded from www Manualslib com manuals search engine...
Страница 21: ...PW II Service Manual 21 5 4 KEY PCB Downloaded from www Manualslib com manuals search engine...