19
* Weight Data (8 byte)
a. 13.5kg : ' ', ' ', ' ', ' ', '1', '3', '.', '5'
b. 135kg : ' ', ' ', ' ', ' ', '1', '3', '5', ' '
c. -135kg : '-', ' ', ' ', ' ', '1', '3', '5', ' '
3) Command mode (F22-3 command mode)
Command
Function
Response
dd RW CR LF
Reads the weight
If dd RW CR LF is received, the indicator
will send the 22byte.
dd MZ CR LF
Same as ZERO key
If dd MZ CR LF is received, the display
shows ZERO and dd MZ CR LF will be
sent to PC.
dd MT CR LF
Same as TARE key
If dd MT CR LF is received, tare is activated
so ZERO, TARE lamp is on and dd MT CR
LF will be sent to PC.
dd HI 00000 CR LF
Enter high limit value
(Except NT-501A)
Change the high limit value to 00000 (no
decimal point) and dd HI 00000 CR LF will
be sent to PC.
dd LO 00000 CR LF
Enter low limit value
(Except NT-501A)
Change the lower limit value to 00000 (no
decimal point) and dd LO 00000 CR LF will
be sent to PC.
dd HE 00000 CR LF
Enter high fall value
(Except NT-501A)
Change the high fall value to 00000 (no
decimal points) and dd HE 00000 CR LF
will be sent to PC.
dd LE 00000 CR LF
Enter high fall value
(Except NT-501A)
Change the low fall value to 00000 (no
decimal point) and dd LE 00000 CR LF will
be sent to PC.
dd PN 00 CR LF
Enter ID(00~50)
Change the ID and dd PN 00 CR LF will be
sent to PC.
dd OP CR LF
Use as START key
(Except NT-501A)
If dd OP CR LF is received, the indicator will
start in packer mode and dd OP CR LF will
be sent to PC.
(You have to set F40 to Packer mode)
dd EM CR LF
Use as STOP key
(Except NT-501A)
If dd EM CR LF is received, the indicator
will stop in packer mode and dd EM CR LF
will be sent to PC.
(You have to set F40 to Packer mode)
dd : Device number
☞
00000 : High limit value / low limit value/ high fall value/ high fall value
☞
(If the setting value is “00345”, ASCII CODE is 0×30(hex), 0×30(hex), 0×33(hex),
0×34(hex), 0 ×35(hex))
* If the command is not accepted for any reason, I CR LF will be sent to PC.
* If an invalid character is received, ? CR LF will be sent to PC.
Содержание NT-500 Series
Страница 1: ...2 ...
Страница 8: ...9 4 Measure of Appearance ...
Страница 9: ...10 5 Front Panel ...
Страница 58: ...59 14 Sealing Method Rear panel sealing Load cell connector sealing ...
Страница 61: ...62 MEMO ...
Страница 62: ...63 MEMO ...
Страница 63: ...64 MEMO ...
Страница 64: ...65 MEMO ...
Страница 65: ...66 MEMO ...
Страница 66: ...67 ...