3-5-1. Status Lamp (ANNUNCIATORS) : Green Color
Lamp is “ON”.
Steady
When the weight is Steady, “▼” Lamp is turn on.
Zero
When the
current weight is Zero, “▼” Lamp is turn on.
(Displayed weight is Zero, “▼” Lamp is turn on.)
Tare
Tare function is set, “▼” Lamp is turn on.
(Tare Reset
“▼” Lamp is turn off.)
SP1
SP1 Relay output Lamp
SP2
SP2 Relay output Lamp
SP3
SP3 Relay output Lamp
SP4
SP4 Relay output Lamp
RTxd
When indicator transfers or receives data from other devices, Lamp is turn
on. (If the Lamp is off although there is some data transference, please
check communication settings).
3-5-2. Key Pad Function
Make Weight value as Zero.
Under F08, you can set the Zero key operation range, as 2%, 5%, 10%,
20% or 100% of Max. Capacity.
※
Under “Tare” key input, Zero key will not be activate within operation
range.
Make Weight value as Zero, including Tare Weight.
Under F09, you can set the Tare key operation range, as 10%, 20%, 50%,
or 100% of Max. Capacity.
※
Whenever pressing “Tare” key, you can set the Tare continuously.
TARE RESET
1. Remove the Set TARE function.
- If you press this key, TARE set value will be removed and display gross
weight.
HOLD RESET
1. Remove the Set HOLD function.
- If you press this key, HOLD set value will be removed.
Start Weighing process, under Packer Mode, only.
Stop weighing process, under Packer Mode, only.