20
/
44
◆
Weighing Mode 1. Limit Mode 1. (F21-01 setting) -
Relay “ON” when weight reaches to set
value
1. Set value setting
Sp1(Bulk), Sp2(Bulk + Drib), Sp3(Bulk + Drib + Fall), Sp4(FINAL)
2. Finish relay output delay time(t1) setting : F-Function 22
3. Finish relay output “ON” time(t2) setting : F-Function 23
※
Finish Relay will be “OFF”, after “t2” time set or weight is under “Empty Range”.
4. Output Relay
Relay
Contents
Relay
Contents
SP 1
Current weight ≥ SP1(ON)
Current weight < SP1(OFF)
SP4
Current weight ≥ SP4(ON)
Current weight < SP4(OFF)
SP 2
Current
weight ≥ SP2(ON)
Current weight < SP2(OFF)
FINISH
After “t1” time,
“On” during “t2” time
SP3
Current weight ≥ SP3(ON)
Current weight < SP3(OFF)
Near Zero
Within “EMPTY” range (ON)
Sp1
Sp2
Sp3
Sp4
t1
Weight
Near Zero
TARE(IN)
SP1
SP2
SP3
SP4
FINISH
Near Zero
t2
Output 1
Output 6
Output 2
Output 3
Output 4
Output 5