FUNCTION 3: Read holding registers
Request
Address Funcion
Register1
Address
No. register
2 bytes
A 0x03
0x0000
0x0002
CRC
Total. bytes = 8
Reply
Address Funcion No.bytes Register1 Register2 2
bytes
A 0x03
0x04
0x0064
0x00C8
CRC
Total. bytes = 3 + 2*No. re 2
-number of register = number of modbus register to be read, start at address 1 register.
-number of byte = number of bytes in the following data
FUNCTION 16: Preset multiple registers
Request
Addr Funcion
Add.
Reg.1
No.reg. No.
bytes
Val. Reg.
1
Val. Reg.
2
2 bytes
A
0x10 0x0000 0x0002 0x4 0x0000 0x0000 CRC
Total. bytes = 7 + 2*No. re 2
Reply
Address Funcion Add.Reg.1 No.reg. 2
bytes
A 0x10
0x0000
0x0002
CRC
Total. bytes = 8
-No. registers = number of modbus register to be read, start at address 1 register
-No. bytes = Number of following data bytes
-Val.reg.1 = Content of starting register
In the reply, the number of converted redcodes starting from address 1 is included.
Содержание EXI-200AD
Страница 1: ... 2 이미지 추가 ...
Страница 20: ...21 4 External Explanation 4 1 External Specifications ...
Страница 28: ...29 2 DCType ...
Страница 29: ... 30 5 1 2 Load Cell Connector ...
Страница 31: ... 32 5 1 3 RS 232 RS 485 Connector RS 485 RS 232 COM2 RS 232 COM1 ...
Страница 86: ...87 Weight Date 8 byte Byte No Example weight 1 2 3 4 5 6 7 8 13 5kg 1 3 5 135kg 1 3 5 135kg 1 3 5 ...
Страница 98: ...99 MEMO ...
Страница 99: ... 100 MEMO ...
Страница 100: ...101 ...