![CAS EXI-200AD Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/cas/exi-200ad/exi-200ad_manual_2565960069.webp)
`
70
9.6 Relay Setting
Menu-F5.01: Set Relay mode
Function
Set Relay mode
Display Part
Meaning
5-01. 0
Limit Mode
5-01. 1
Limit type Checker Mode
5-01. 2
Checker Mode
Set Range
(0 ~ 3)
5-01. 3
Programmable Mode
<Limit Mode>
Note.
1. Set value input requirement: SP2 > SP1
2. Relay Output
Step 1 : W
≥
SP1
ON
Step 2 : W
≥
SP2
ON
Finish : W
≥
SP2 & Stable
ON
Near zero : Set value
≥
0 range output