30
Menu-GEN.14: Set Hold Canceling Conditions
Function
Hold Canceling Conditions Setting
Display Part
Meaning
HD-C.00
Hold is canceled when it becomes zero
HD-C.01
Hold is canceled when Hold key is entered
Set Range
(0~2)
HD-C.02
Hold is canceled when Hold less key entered
Menu-GEN.15: Set average hold time
Function
Set average hold time
Display Part
Meaning
Set Range
(1~99)
HD-T. XX
Initial Value :
30 x 0.1 sec
When the weight change width changes within the automatic hold
range setting value, auto hold operation after set value x 0.1 second.
Menu-GEN.16: Set Auto Hold Range
Function
Set auto hold range
Display Part
Meaning
Set Range
(5~50)
AH-S. XX
Initial Value :
10 x 1 Digit
Auto hold operation when weight change width is less than
set value. x 1 digit.
Menu-GEN.17: Set Auto Hold Canceling Range
Function
Set auto hold canceling range
Display Part
Meaning
Set Range
(2~99)
AH-R. XX
Initial Value :
10 %
Auto hold cancel when weight change width is larger than
set value
Menu-GEN.18: Set the use of set key.
Function
Set the use of set key
Display Part
Meaning
FKEY.00
Set key used as the hold key.
FKEY.01
Set key used as the total print key.
Set Range
(0~2)
FKEY.02
Set key used as the start key.
Menu-GEN.19: Initializing of set values
Function
Initializing of set values
Display Part
Meaning
INIT. 0
No set values of the product are initialized to factory shipping state
Set Range
(0, 1)
INIT. 1
All set values of the product are initialized to factory shipping state
Содержание CI-150A
Страница 1: ...2 ...
Страница 3: ...4 ...
Страница 4: ...5 ...
Страница 8: ...9 MEASURE OF APPEARANCE ...
Страница 55: ...56 Weight Date 8 byte Byte No Example weight 1 2 3 4 5 6 7 8 13 5kg 1 3 5 135kg 1 3 5 135kg 1 3 5 ...
Страница 66: ...67 MEMO ...
Страница 67: ...68 MEMO ...
Страница 68: ...69 MEMO ...
Страница 69: ...70 ...