38
5. Analogue Output Setting (Option)
Menu-AOUT.01: A-out activation range setting
Function
Set A-Out range
Display Part
Meaning
AOBI. 0
Unipolar(operating in +weight)
Set Range
(0, 1)
AOBI. 1
Bipolar(operating in ±weight)
Menu-AOUT.02: V-out range setting
Function
V-out range
Display Part
Meaning
VRAN. 0
V-out is closed
VRAN. 1
0V ~ 5 V
VRAN. 2
0V ~ 10 V
VRAN. 3
±5 V
Set Range
(0~4)
VRAN. 4
±10 V
Note 1. Simultaneous output is not used. Therefore the V-out output range settings are applied with priority
during setting.
Note 2. When only using I-out, the V-out output range must be set to 0.
Menu-AOUT.03: I-out range setting
Function
I-out range
Display Part
Meaning
IRAN 0
I-out is closed
IRAN. 1
4 mA ~ 20 mA
IRAN. 2
0 mA ~ 20 mA
Set Range
(0 ~ 3)
IRAN. 3
0 mA ~ 24 mA
Menu-AOUT.04: Dual output(V-out & I-out)
Function
Dual output(V-out & I-out)
Display Part
Meaning
DUON. 0
Dual output disabled
Set Range
(0, 1)
DUON. 1
Dual output enabled
Menu-AOUT.05: Minimum weight of A-out
Function
Minimum Output Weight Value upon Using Analog Out option
Display Part
Meaning
Set Range
(0 ~ Max weight)
1000
2000
Initial value : 0
Minimum output at 1000 kg
Minimum output at 2000 kg
Содержание CI-150A
Страница 1: ...2 ...
Страница 3: ...4 ...
Страница 4: ...5 ...
Страница 8: ...9 MEASURE OF APPEARANCE ...
Страница 55: ...56 Weight Date 8 byte Byte No Example weight 1 2 3 4 5 6 7 8 13 5kg 1 3 5 135kg 1 3 5 135kg 1 3 5 ...
Страница 66: ...67 MEMO ...
Страница 67: ...68 MEMO ...
Страница 68: ...69 MEMO ...
Страница 69: ...70 ...