19
CAL 3
CAL 3-1
Function : Setting Multi Calibration Step
Range of set value : 1 ~ 5
KEY
DISPLAY
DESCRIPTION
STEP- 1
Setting multi calibration for step 1
(CAL3-3 and CAL 3-4 are carried out once)
▲
,
▼
Key : Value change
ZERO Key : Cancel
SET Key : Save and next
menu
STEP- 5
Setting multi calibration for step 5
(CAL3-3 and CAL 3-4 are carried out five times.)
►
Note 1. A function to use, when the output of load cell is corrected by setting multiple
points in some sections because the actual curve of load cell is not a straight line.
(zero span)
Zero and Span points to interpolate weight from Load Cell
Multi-point
Multi-point
mV/V
Real curve
weight
(full span)
Multi-point
Ideal
Multi-point
Multi-point
CAL 3-2
Function: Zero Calibration
KEY
DISPLAY
DESCRIPTION
UnLoAd
Empty the load tray and press the setup key.
1234
The current weight value is displayed.
Confirm 'Stable' and press the setup key.
ZERO Key : Cancel
SET Key : Save and next
menu
- - -
Zeroing in progress...
►
Note 1. If zeroing finished with no error, it moves to Setting Weight (CAL 3-3) although
no key is pressed.