OWNER’S MANUAL
SYSTEM OPERATING INFORMATION
92
7
5137 • C8 12/2016
the left and then pushing down on the top of the yellow
switch. The ACR will remain on for 10 minutes after
manual engagement and will then turn off automatically if
predetermined battery voltage levels have been met. The
ACR can be turned off by turning the yellow switch to the
right. When in this position, the ACR is in the LOCKED
OFF position and its automatic function is inoperative.
OTE:
N
The engine ACR can also be used as a
battery parallel should one of the engine
batteries be consumed to an unusable
voltage level. Whenever the engine ACRs
are engaged, the engine batteries are
paralleled.
Fuse Holders
The fuse holders under the master disconnect switches
supply operation current to the master disconnect
switches.
•
Fuse holders with purple and white wires are 10 amp
fuses.
•
Fuse holders with orange and red wires are 3 amp
fuses.
Engine Batteries and Master
Disconnect Switches
Each propulsion engine has two designated engine
batteries. Each engine battery set is located outboard of
the designated engine.
A master disconnect switch controls the electricity from
each battery to the battery’s designated engine. Turn ON
the master disconnect switches to provide electricity to
the engines.
Accessory Battery and Master
Disconnect Switch
The accessory equipment is controlled by the DC control
center. The DC control center is powered by a single 12-
volt accessory battery.
Electricity from the accessory battery is controlled by a
master disconnect switch. Circuit breakers on the DC
control center control the fl ow of electricity to the other
DC circuit breaker panels.
Generator Battery and Master
Disconnect Switch
The generator has a single, dedicated battery. Electricity
from the battery to the generator starter is controlled by a
master disconnect switch.
The master disconnect switch for the generator is
mounted on the generator. The master disconnect switch
can be operated manually at the generator or with the
remote switch at the DC control center.
Turn ON the GENERATOR master disconnect switch to
provide electricity to the generator starter.
There are two fuse holders at the generator master
disconnect switch.
ENGINE ROOM THERMAL
CIRCUIT BREAKERS
The thermal circuit breakers in the engine room will trip in
the event of overcurrent to the labeled components.
DC CONTROL CENTER
The DC control center manages the power supply to the
DC components listed on the panel. The yacht contains
a single DC control center. The center contains circuit
breakers, additional controls and meters as described in
the vendor literature.
Remote Switches
The remote switches allow remote operation of the
master disconnect switches in the engine room.
OTE:
N
The yellow switch on top of the master
disconnect switch in the engine room
must be turned to the left-hand position
(REMOTE) in order for the remote switch on
the DC control center to operate.
Содержание C52 Coupe
Страница 1: ......
Страница 38: ...33 5137 C8 12 2016 OWNER S MANUAL YACHTING SAFETY 2 7151103 Figure 2 27 Dockside Cord Male End...
Страница 40: ...35 5137 C8 12 2016 OWNER S MANUAL YACHTING SAFETY 2 7150130 Fire Ext CREW A Figure 2 30 Crew Quarters...
Страница 63: ...OWNER S MANUAL YACHTING SAFETY 58 2 5137 C8 12 2016 Notes...
Страница 77: ...OWNER S MANUAL EMERGENCIES 72 4 5137 C8 12 2016 Notes...
Страница 191: ...OWNER S MANUAL MAINTENANCE AND CARE 186 9 5137 C8 12 2016 Notes...
Страница 192: ...187 5137 C8 12 2016 OWNER S MANUAL MAINTENANCE AND CARE 9...
Страница 200: ...OWNER S MANUAL WINTERIZATION AND STORAGE 194 5137 C8 12 2016 10...
Страница 201: ...CARVER YACHTS PO BOX 1010 PULASKI WI 54162 1010 CARVER YACHTS PO BOX 1010 PULASKI WI 54162 1010...
Страница 202: ......